| Date |
Text |
| 2007-04-24 16:55:56 | DENIED |
| | REFERENCE: |
| | ** FBC-2004 PLUMBING. |
| | ** FBC-2004 CHAPTER 1, THE CITY OF |
| | WEST PALM BEACH AMENDMENTS. |
| | |
| | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR |
| | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: |
| | |
| | 1. SHEET 2 OF 4 FLOOR PLAN IS INDICATING THE PLUMBING |
| | FIXTURES IN THE PROPOSED BATHROOM AS BEING A LAVATORY, |
| | WATER CLOSET AND A TUB. SHEET 4 OF 4 SANITARY ISOMETRIC |
| | RISER DIAGRAM IS INDICATING THE PLUMBING FIXTURES IN |
| | THE PROPOSED BATHROOM AS BEING A SINK, WATER CLOSET, |
| | AND A SHOWER. PLEASE CORRELATE AND CORRECTLY IDENTIFY |
| | THE PLUMBING FIXTURES IN THE RESUBMITTAL AS PER |
| | FBC-2004 CHAPTER 1, SECTION 106.1.1 INFORMATION ON |
| | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY |
| | TO LOCATION, NATURE, AND THE EXTENT OF THE WORK. PLEASE |
| | NOTE THAT PLUMBING FIXTURES SHALL BE PROPERLY |
| | IDENTIFIED AS PER FBC-2004 PLUMBING CHAPTER 4 |
| | FIXTURES. |
| | |
| | 2. SHEET 4 OF 4 SANITARY ISOMETRIC RISER DIAGRAM IS |
| | INDICATING A TRAP FOR THE WATER CLOSET. PER FBC-2004 |
| | PLUMBING, SECTION 1002.1 A FIXTURE SHALL NOT BE DOUBLE |
| | TRAPPED. PLEASE NOTE THAT A WATER CLOSET HAS AN |
| | INTEGRAL TRAP AND A TRAP NEED NOT BE INDICATED. PLEASE |
| | CORRECT ON THE RESUBMITTAL AND PLEASE NOTE THIS FOR |
| | FUTURE SANITARY ISOMETRIC PLUMBING RISER DIAGRAMS. |
| | |
| | ********IMPORTANT INFORMATION******** |
| | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, |
| | PLEASE REPLACE ONLY SHEETS |
| | WHICH HAVE CHANGED, PLEASE INCLUDE A |
| | TRANSMITTAL LETTER INDICATING HOW EACH |
| | ITEM WAS ADDRESSED AND PROVIDE ONE COPY |
| | OF ALL OLD/VOIDED SHEETS FOR REFERENCE |
| | ONLY. |
| | NOTE: ONLY ONE CORRECTED DRAWING |
| | IN RED INK FOR REFERENCE FOR |
| | RESUBMITTAL. |
| | |
| | END OF COMMENTS: |
| | |
| | REVIEW BY MIKE PERSON |
| | (561) 805-6730 |
| | FAX (561) 805-6731 |
| | E-MAIL [email protected] |
| | UNDER SUPERVISION OF K.STEVENS |
| | (561) 805-6721 |