| 2007-07-05 14:02:11 | **FAILED** FOR FOLLOWING REASONS: |
| | |
| | 1. SHEETS 2 OF 9, & 5 OF 9 OF SIMMON & WHITE, HAVE |
| | RUBBER STAMP PE BY MR. BOLEN AND METAL SEAL BY |
| | DIFFERENT PE, THAT IS NOT ALLOWED BY FBPE |
| | 2. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI) FROM |
| | FDEP. YOU NEED TO APPLY AT FDEP FOR NOI. |
| | 3. PLEASE SHOW STANDARDS NOTES OF CITY OF WPB ON |
| | DRAWINGSFOR SIDEWALK WIDTH , ITS SLOPE, DRIVEWAY, |
| | PARKING, HANDICAP PARKING, PAINTING DETAILS FOR PARKING |
| | PER CITY CODES ETC.,, MUST MEET PER ADA,,ETC.,YOU CAN |
| | GET STANDARD NOTES OF CITY OFWPB IN A C.D. FROM 1000 |
| | 45TH STREET. ENG DEPT.WE SHOULD HAVE THOSE NOTES ON |
| | YOUR DRAWINGS. |
| | 4. DO YOU HAVE DUMPSTER? IF YOU DO, PLEASE SHOW ON |
| | DRAWINGSDUMPSTER & ITS ENCLOSURE DETAILS PER CITY OF |
| | WPB, &LOCATION ON DWG, LOCATION MUST BE ACCESSIBLE |
| | FOR PICKUP TRUCK. |
| | 5. FIRST FLOOR ELEVATION, CENTER LINE OF ROAD , |
| | SIDEWALK ELEVATION MUST MEET FLOOD ZONE AREA, & 5,10, |
| | 25, 100 YEAR FLOOD CRITERIATO DETERMINE THE FIRST |
| | FLOOR ELEVATION, MUST MEET MINIMUM REQUIREMENTS, PLEASE |
| | SHOW IN THE CALCULATION. |
| | 6.PLEASE SHOW STORM WATER QUALITY CALCULATIONS, WHAT |
| | CRITERIA YOU ASSUMEDFOR RUNOFF CAL.,, LIKE 1" OVER |
| | ENTIRE SITE OR2.5"CRITERIA, ETC, ? PLEASE SHOW IN |
| | THE CALCULATIONS. |
| | 7. HOW YOU CONNECT TO THE STORM WATER PIPES IN YOUR |
| | SITE? PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR |
| | SITE SO, WE CANSEE THE BEST PIPE TO CONNECT WITH THE |
| | STORM WATER FROM ALL OTHER STORM WATER PIPES. |
| | 8. PLEASE SHOW POLLUTION PREVENTION DETAILS,CLOTHES |
| | USED FOR SILT ETC., PLANS SHOWING SILT FENCE AROUND THE |
| | SITE & CATCH BASINS.HEIGHT OF FENCE SHOULD BE HIGH |
| | ENOUGH PER FDEP TO STOP DUST & PARTICLES. |
| | |
| | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR |
| | PERMITTING PROCESS |
| | |
| | RASIK CHOKSHI805-6723 |