2007-06-11 11:33:13DENIED
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. MORE INFORMATION IS REQUIRED ON THE DRAWINGS DUE TO
 THE FIRE DAMAGE.
 A} IF PLUMBING LAYOUT IS THE SAME
 WITH NO CHANGES AND FIRE DAMAGE, PLEASE INDICATE THIS
 ON
 THE DRAWING.
 B} IF PLUMBING LAYOUT IS THE
 SAME AND THE PLUMBING FIXTURES ARE TO BE
 CHANGED DUE TO FIRE DAMAGE, PLEASE INDICATE THIS ON THE
 DRAWING.
 "EXACT FIXTURE CHANGE OUT ONLY."
 C} IF PLUMBING (SANITARY) PIPE WAS DAMAGED BY THE FIRE
 AND NEEDS TO BE REPLACED PLEASE FOLLOW WHAT IS REQUIRED
 IN COMMENT #2.
  
 2. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4
 RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A
 PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING
 ALL WASTE, VENTS, TRAPS AND SIZES WITH CLEANOUT
 LOCATIONS.
  
 3. NOTE: PER FBC-2004 PLUMBING, TABLE 403.1 THAT ONE
 (1) AUTOMATIC CLOTHES WASHER CONNECTOR PER DWELLING
 UNIT REQUIRED AND NEEDS TO BE INDICATED ON THE
 RESUBMITTED DRAWINGS.
  
 END OF COMMENTS:
  