| Date |
Text |
| 2007-03-15 16:01:13 | BUILDING PLAN REVIEW |
| | PERMIT:07030261 |
| | ADD: 5913 S.DIXIE HWY |
| | CONT: |
| | TEL: (561)###-#### |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2006 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) FL S S 713.13 |
| | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF |
| | THE COURT. |
| | NOTE: 713.13(2) |
| | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS |
| | NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE |
| | RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: |
| | 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT |
| | THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| | |
| | 3)110.2* W. P. B. ADMINISTRATIVE |
| | CODE, INFORMATION THAT IS REQUIRED FOR |
| | RECORD KEEPING & FOR CERTIFICATE OF |
| | OCCUPANCY: |
| | A) THE EDITION OFTHE CODE UNDER WHICH |
| | THE PERMIT WAS ISSUED. |
| | B) THE USE AND OCCUPANCY, IN ACCORDANCE |
| | WITH THE PROVISIONS OF CHAPTER 3. |
| | C) THE TYPE OF CONSTRUCTION AS DEFINED |
| | IN CHAPTER 6, TABLE 601. |
| | D) THE DESIGN OCCUPANT LOAD, SEE 1004. |
| | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS |
| | PROVIDED, WHETHER THE SPRINKLER SYSTEM |
| | IS REQUIRED. |
| | ) NUMBER OF UNITS |
| | ) NUMBER OF FLOORS |
| | ) SQ. FT. FOOTPRINT |
| | ) SQ. FT. UNDER ROOF (TOTAL) |
| | ) OCCUPANT LOAD |
| | THIS INFORMATION IS REQUIRED TO DETERM THE WIDTH OF THE |
| | STAIRS. FBC 1005.1 THE TOTAL WIDTH OF MEANS OF EGRESS |
| | IN INCHES SHALL NOT BE LESS THAN THE TOTAL OCCUPANT |
| | LOAD SEVED BY THE MEANS OF EGRESS MULTIPLIED BY THE |
| | FACTORS IN TABLE 1005.1. |
| | FBC. 1004.1 IN DETERMINING MEANS OF EGRESS |
| | REQUIREMENTS,THE MUMBER OF OCCUPANTS FOR WHOM NEANS OF |
| | EGRESS FACILITIES SHALL BE PROVIDED SHALL BE |
| | ESTABLISHED BY THE LARGEST NUMBER COMPUTED IN |
| | ACCORDANCE WITH SECTIONS 1004.1 THROUGH 1004.1.3 |
| | |
| | 4)PROVIDE AN EXISTING AND PROPOSED FLOOR PLAN. SHOW |
| | THE MEANS OF EGRESS FOR THE SECOND FLOOR ON THE |
| | EXISTING FLOOR PLAN AND SHOW THE NEW SET OF STAIRS ON |
| | THE PROPOSED FLOOR PLAN. |
| | |
| | 5)FBC.1007.1STAIRS REQUIRED TO BE ACCESSIBLE SHALL |
| | COMPLY WITH SECTIONS FBC 11-4.9 |
| | |
| | 6)FBC. 11-4.9.4STAIRWAYS SHALL HAVE HANDRAILS AT |
| | BOTH SIDES OF ALL STAIRS, HANDRAILS SHALL COMPLY WITH |
| | SEC. 11-4.26 AND FIG, 19A AND 19B. THEY SHALL EXTEND AT |
| | LEAST 12 INCHES BEYOND THE TOP RISER AND 12 INCHES PLUS |
| | THE WIDTH OF ONE TREAD BEYOND THE BOTTOM RISER. |
| | |
| | 7)FBC. 11-4.13.6MINIMUM MANEUVERING CLEARANCE AT |
| | DOORS THAT ARE NOT AUTOMATIC OR POWER-ASSISTED SHALL BE |
| | AS SHOWN IN FIG. 25THE FLOOR OR GROUND AREA WITHIN |
| | THE REQUIRED CLARANCES SHALL BE LEVEL AND CLEAR. |
| | |
| | 8)THE H/C BATH SHALL BE IN COMPLIANCE WITH FBC |
| | 11-4.17.SHOW THE CLEAR FLOOR SPACE FOR THE TOILET |
| | STALL. SEE FIG 30A / 30E AND FIG 28 CH.11 FOR MORE |
| | INFORMATION. |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | 805-6726 |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |