2007-07-31 13:30:44****************PROVISO****************
 PER FBC-2004 PLUMBING SECTIONS 424.3 AND P2708.3 SHOWER
 VALVES: SHOWER AND TUB/SHOWER COMBINATIONS SHALL BE
 EQUIPPED WITH CONTROL VALVES OF THE PRESSURE BALANCE,
 THE THERMOSTATIC MIXING OR THE COMBINATION PRESSURE
 BALANCE/THERMOSTATIC MIXING VALVE TYPES WITH HIGH LIMIT
 STOPS IN ACCORDANCE WITH ASSE 1016. THE HIGH LIMIT
 STOPS SHALL BE SET TO LIMIT WATER TEMPERATURE TO A
 MAXIMUM 120 DEGREES FAHRENHEIT.
  