| 2007-03-16 15:08:22 | DENIED |
| | REFERENCE: FBC-2004 PLUMBING;FBC-2004 CHAPTER 1, THE |
| | CITY OF WEST PALM BEACH AMENDMENTS; |
| | |
| | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING |
| | PLAN REVIEW TO MEET CODE COMPLIANCE: |
| | |
| | 1. SHEET 13, SANITARY ISOMETRIC RISER DIAGRAM.PER |
| | FBC-2004 CHAPTER 1, SECTION 106.1.1 INFORMATION ON |
| | CONSTRUCTION |
| | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL |
| | BE OF SUFFICIENT CLARITY TO INDICATE THE |
| | LOCATION, NATURE AND EXTENT OF THE WORK |
| | PROPOSED AND SHOW IN DETAIL THAT IT WILL |
| | CONFORM TO THE PROVISIONS OF THIS CODE |
| | AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS, |
| | AS DETERMINED BY THE |
| | BUILDING OFFICIAL. |
| | |
| | A} SANITARY ISOMETRIC RISER DIAGRAM DOES NOT REFLECT |
| | THE FLOOR PLAN OF SHEET 2 AND IS NOT CODE COMPLIANT. |
| | |
| | B} FIXTURES ARE IDENTIFIED WRONG, SHEET 2 FIXTURES ARE |
| | A LAVATORY, WATER CLOSET, AND A SHOWER. SHEET 13 |
| | SANITARY RISER DIAGRAM INDICATES A SINK, WATER CLOSET |
| | AND A TUB. PLEASE CORRECT AND RESUBMIT. |
| | |
| | C} SANITARY RISER DIAGRAM ON SHEET 13 IS INDICATING A |
| | DOUBLE SANITARY TEE PER FBC-2004 PLUMBING SECTION 706.3 |
| | IS ILLEGAL ON A HORIZONTAL INSTALLATION. PLEASE CORRECT |
| | AND RESUBMIT. |
| | |
| | D} 708.3.5 BUILDING DRAIN AND BUILDING |
| | SEWER JUNCTION. THERE SHALL BE A TWO-WAY |
| | CLEANOUT NEAR THE JUNCTION OF THE |
| | BUILDING DRAIN AND THE BUILDING SEWER. PLEASE ADD TO |
| | THE RESUBMITTAL. |
| | |
| | ********IMPORTANT INFORMATION******** |
| | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, |
| | PLEASE REPLACE ONLY SHEETS |
| | WHICH HAVE CHANGED, PLEASE INCLUDE A |
| | TRANSMITTAL LETTER INDICATING HOW EACH |
| | ITEM WAS ADDRESSED AND PROVIDE ONE COPY |
| | OF ALL OLD/VOIDED SHEETS FOR REFERENCE |
| | ONLY. |
| | NOTE: ONLY ONE CORRECTED DRAWING |
| | IN RED INK FOR REFERENCE FOR |
| | RESUBMITTAL. PLEASE REFERENCE THE ATTACHED SANITARY |
| | ISOMETRIC RISER DIAGRAM TO THE PLUMBING COMMENTS THAT |
| | REFLECTS THE FLOOR PLAN AND IS CODE COMPLIANT. |
| | |
| | END OF COMMENTS: |
| | |