| Date |
Text |
| 2007-03-09 09:55:32 | PLEASE PROVIDE FOLLOWING INFO: |
| | |
| | 1. STANDARDS NOTES OF CITY OF WPB SHOWN ON DRAWINGS |
| | FOR SIDEWALK WIDTH , ITS SLOPE, DRIVEWAY, PARKING, |
| | HANDICAP PARKING, PAINTPER CITY CODES ETC AETC. ARE |
| | ALL MINIMUM STANDARDS,PLEASE USE LATEST STANADARD NOTES |
| | REVISED IN 2006,MAKE SURE YOU ALSO MEET |
| | FDOT,STATE,HANDICAP ADA,,FDEP ETC., |
| | 2. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE |
| | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION |
| | MUST BE ACCESSIBLE FOR PICKUP TRUCK. |
| | 3. FIRST FLOOR ELEVATION, MUST MEET FL BLDG CODES, |
| | FLOOD ZONE,CENTER LINE OF ROAD , SIDEWALK ELEVATION , |
| | PLEASE SHOW ALL THESE ELEVATIONON THE DRAWINGS. |
| | 4. PLEASE PROVIDE A COPY OF SFWMD PERMIT,GEO-TECH |
| | REPORT, SOIL CONDUCTIVITYETC |
| | 5.PLEASE SHOW STORM WATER CALCULATIONS, WHAT CRITERIA |
| | YOU ASSUMEDFOR RUNOFF CAL.,, LIKE 1" OVER ENTIRE SITE |
| | OR2.5"CRITERIA, ? TOTALPERVIOUS AREA, LIKE GREEN, |
| | LAKES, ETC,IMPERVIOUS AREA CAL., |
| | 6. WHAT IS THE SITE AREA, YOU ARE DEVELOPING FOR THIS |
| | PROJECT ONLY ? SO, PERVIOUS AREA, IMPERVIOUS AREA.ETC? |
| | 7. HOW YOU CONNECT TO THE STORM WATER PIPES IN YOUR |
| | SITE? ITS DETAILS.PLEASE SHOW ALL STORM WATER PIPES |
| | AROUND YOUR SITE SO, WE CANSEE THE BEST PIPE TO |
| | CONNECT WITH THE STORM WATERFROM ALL OTHER STORM |
| | WATER PIPES. PLEASE SHOW DETAIL OF THE CONTROL |
| | STRUCTURES WITH ELEVATIONS, NOTCHES, BLEEDING |
| | ELEVATION, EXFILTRATION TRENCH LENGTH CALCULATIONS. |
| | 8. POLLUTION PREVENTION PRE & POSTLIKE DURING |
| | DEMOLATION AND DURING CONSTRUCTION. PLEASE SHOW SILT |
| | FENCE AROUND THE SITE ALSO DURING DEMOLATION, |
| | DETAILS,CLOTHES USED FOR SILT ETC.,SILT FENCE HEIGHT |
| | SHOWN IN SHEET C-16 & C-8 NOT CONSISTENT. SILT FENCE |
| | HEIGHT SHOULD BE 5 FEET OR ABOVE |
| | 9. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH |
| | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED |
| | 10. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND |
| | YOUR SITE FOR STORM WATER DRAIN. |
| | |
| | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR |
| | PERMITTING PROCESS |
| | |
| | RASIK CHOKSHI805-6723 |