| Plan Review Notes For Permit 07020594 |
| Permit Number |
07020594 |
|
| Review Stop |
E |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2007-02-28 07:30:56 | | | | | | | DENIED/INCOMPLETE INFORMATION | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1} PLEASE SUBMIT A FLOOR PLAN AND INDICATING THE | | | LOCATION OF ALL EQUIPMENT AND DEVICES BEING INSTALLED | | | UNDER THE SCOPE OF THIS APPLICATION.106.1.1 FBC. | | | | | | 2} KITCHEN RECEPTACLE SPACING MUST COMPLY WITH | | | 210.52(A), 210.52(C), AND 210.8(A)(6) GFI. INDICATE | | | SAME ON PLANS. | | | | | | 3} THERE IS MENTION OF DEVICES IN THE BATHROOM. PROVIDE | | | A FLOOR PLAN AND LOCATE THE DEVICES IN ALL AREAS OF | | | WORK. BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE | | | PER 210.11(C) (3), LOCATED PER 210.52(D), AND BE GFI | | | PROTECTED PER 210.8(A) (1). | | | | | | 4} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | | PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.2. FBC. | | | | | | 5} TWO SETS OF ALL DOCUMENTS MUST BE SUBMITTED FOR | | | REVIEW PER 106.1 FBC AS AMENDED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|