| Plan Review Notes For Permit 07020506 |
| Permit Number |
07020506 |
|
| Review Stop |
G |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2007-05-14 10:12:57 | REVISION: NEW LAYOUT WITH ALL NEW PIPING DUE TO DAMAGED | | | EXISTING. | | | | | | ****************PROVISO**************** | | | IF DRYER ROOM IS A CONFINED SPACE, OPEN- | | | INGS REQUIRED PER SECTION 304.5 OR | | | SECTION 304.6 SHALL BE INSTALLED. | | | MINIMUM 1,100 CUBIC FEET REQUIRED. | | | | | | A} PER FBC-2004 FUEL GAS, SECTION 404.13.3AN | | | INSULATED COPPER TRACER WIRE SHALL BE INSTALLED | | | ADJACENT TO UNDERGROUND NONMETALLIC GAS PIPING. THE | | | TRACER WIRE SIZE SHALL NOT BE LESS THAN 18 AWG AND THE | | | INSULATION TYPE SHALL BE SUITABLE FOR DIRECT BURIAL. | | | | | | B} FBC-2004 FUEL GAS SEC. 404.12 OUTLET | | | CLOSURES: GAS OUTLETS THAT DO NOT CON- | | | NECT TO APPLIANCES SHALL BE CAPPED GAS | | | TIGHT. |
|