Plan Review Notes
Plan Review Notes For Permit 07020398
Permit Number 07020398
Review Stop Z
Sequence Number 2
Notes
Date Text
2007-04-12 14:45:49PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1.SITE PLAN SHALL BE MODIFIED TO REFLECT EXISTING
 CONDITIONS SHOWN ON THE SURVEY.
 A.SURVEY SHOWS A 5 FOOT UTILITY EASEMENT ALONG THE
 SOUTH PROPERTY LINE; HOWEVER, SITE PLAN SHOWS A 2.5
 FOOT EASEMENT.
 B.SURVEY SHOWS A SIDE SETBACK DIMENSION OF 6 FEET TO
 THE EAST; HOWEVER, SITE PLAN SHOWS A SIDE SETBACK
 DIMENSION OF 5 FEET 3.5 INCHES.
  
 2.SURVEY MUST SHOW SIDE SETBACK DIMENSIONS OF
 EXISTING BUILDING TO THE WEST PROPERTY LINE.
  
 3.PLEASE NOTE THAT PER SECTION 94-72 OF THE ZONING
 AND LAND DEVELOPMENT REGULATIONS, SIDE SETBACK IS 15
 FEET TOTAL.
  
 4.LOCATION OF A/C UNITS SHALL BE SHOWN ON THE SITE
 PLAN WITH SETBACK DIMENSIONS FROM PROPERTY LINE. PLEASE
 NOTE THAT PER SECTION 94-305(B)(4), MECHANICAL
 EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET INTO A
 SETBACK.REQUIRED REAR SETBACK IS 10.19 FEET.
  
 COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.