Plan Review Notes
Plan Review Notes For Permit 07020305
Permit Number 07020305
Review Stop B
Sequence Number 1
Notes
Date Text
2007-02-14 18:59:39BUILDING PLAN REVIEW
 PERMIT:
 ADD:
 CONT:
 TEL: (561)###-####
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
  
 2) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF
 THE COURT.
 NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS
 NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE
 RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE:
 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT
 THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 3)FBC 11-5.2 COUNTERS AND BARS (WINE TASTING AREA)
 WHERE FOOD OR DRINK IS SERVED @ COUNTERS
 EXCEEDING 34" IN HEIGHT FOR CONSUMPTION
 BY CUSTOMERS SEATED ON STOOLS OR STAND-
 ING AT THE COUNTER, A PORTION OF THE
 MAIN COUNTER WHICH IS 60" IN LENGTH MIN-
 IMUM SHALL BE PROVIDED IN COMPLIANCE
 WITH 11-4.32 OR SERVICE SHALL BE AVAIL-
 ABLE AT ACCESSIBLE TABLES WITHIN THE
 SAME AREA. PROVIDE AN ELEVATION DRAWINGS OF THIS AREA
 WITH THE DIMENTIONS WHICH SHALL MEET THE REQUIREMENTS
 OF THIS SECTION.
  
 4)FBC 11-4.3ALL WALKS, HALLS, CORRIDORS, ASILES,
 SKYWALKS, TUNNELS, AND OTHER SPACES THAT ARE PART OF AN
 ACCESSIBLE ROUTE SHALL COMPLY WITH SECTION 11-4.3 SHOW
 COMPLIANCE.
  
 5)FBC 11-7.2SALES AND SERVICE COUNTERS, TELLER
 WINDOWS, INFORMATION COUNTERS SHALL HAVE A SECTION OF
 THE COUNTER AT LEAST 36 INCHES IN LENGTH WITH A MAXIMUM
 HEIGHT OF 36 INCHES ABOVE THE FINISH FLOOR. SEE SECTION
 11-7 FOR MORE INFORMATION AND SHOW THE ELEVATION
 DETAILS OF THE COUNTERS AT THE COUNTERS.11-7.3 AT LEAST
 ONE CHECK-OUT AISLE SHALL BE ACCESSIBLE.
  
 5)THE VALUE IS TO LOW. WPB AMENDMENTS 108.3.IF, IN
 THE OPINION OF THE BUILDING OFFICIAL. THE CLAIMED
 VALUATION OF THE BUILDING ALTERATION, APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION. THE PERMIT SHALL BE
 DENIED. OUR VALUATION REFERENCES IS ICC (BVD),
 MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES.
  
 6)WHAT IS THE PURPPOSE OF THE KIDS ROOM?
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  
  
  
  
  