| Date |
Text |
| 2007-07-14 07:47:52 | DENIED |
| | REFERENCE: FBC-2004 PLUMBING |
| | FBC-2004 CHAPTER 1 |
| | FBC-2004 CHAPTER 11 |
| | FBC-2004 BUILDING |
| | FLORIDA ADMINISTRATIVE CODE |
| | FLORIDA STATUTES |
| | |
| | ****FROM PREVIOUS REVIEW**** |
| | |
| | 1. OK |
| | |
| | 2. SHOW THE SQUARE FOOTAGE OF THE BUILDING ON THE |
| | PLANS. SECTION 106.1.2. |
| | ****NO RESPONSE/NOT ADDRESSED |
| | |
| | 3. OK |
| | 4. OK |
| | |
| | 5. SUBMIT CALCULATIONS FOR MINIMUM FACILITIES. AS SHOWN |
| | THERE APPROXIMATELY 1,158SSF NET DIVIDED BY 5 NET AS |
| | INDICATED IN TABLE 1004.1.2 THERE ARE 232 OCCUPANTS. |
| | PER TABLE 403.1 232 DIVIDED BY 2 EQUALS 116 MEN - 116 |
| | WOMEN. DIVIDED BY 40 EQUALS 2.9 OR 3 WATER CLOSETS EACH |
| | REQUIRED FOR MEN AND WOMEN, WITH 2 LAVS EACH FOR MEN |
| | AND WOMEN. |
| | ****NO RESPONSE/NOT ADDRESSED |
| | |
| | 6. OK |
| | |
| | 7. SHT 2 SHOW THE CLEAR FLOOR SPACE FOR ALL ACCESSIBLE |
| | FIXTURES ON THE FLOOR PLAN. THE DRINKING FOUNTAIN IS |
| | REQUIRED TO BE 15" OFF THE WALL AND CENTERED ON THE 30" |
| | WIDTH OF THE CLEAR FLOOR SPACE. AS SHOW THE SERVICE |
| | SINK IS ENCROACHING INTO THE CLEAR FLOOR SPACE OF THE |
| | DRINKING FOUNTAIN. |
| | ****NO RESPONSE/NOT ADDRESSED |
| | |
| | 8. THE ACCESSIBLE STALL SHALL COMPLY WITH FIGURE |
| | 11-30E. A LAV IS REQUIRED IN THE STALL AND 5' OF CLEAR |
| | FLOOR SPACE IS REQUIRED FROM THE WALL ADJACENT TO THE |
| | WATER CLOSET AND UP TO THE SIDE OF THE LAV. SECTION |
| | 11-4.17.3 EXCEPTIONS (1)(2). |
| | ****NO RESPONSE/NOT ADDRESSED |
| | |
| | 9. OK |
| | |
| | ***********NEW COMMENTS*********** |
| | |
| | 1B. SUBMIT A DETAIL FOR THE W/C'S SHOW COMPLIANCE WITH |
| | THE FOLLOWING: |
| | A. 11-4.16.2 CLEAR FLOOR SPACE |
| | B. 11-4.16.3 HEIGHT |
| | C. 11-4.16.4 GRAB BARS |
| | D. 11-4.16.5 FLUSH CONTROLS |
| | E. 11-4.16.6 DISPENSERS |
| | |
| | 2B. SUBMIT A DETAIL FOR THE STALLS SHOWING COMPLIANCE |
| | WITH THE FOLLOWING: |
| | A. 11-4.17.3 SIZE & ARRANGEMENT (EXCEPTION NEW |
| | CONSTRUCTION) (FIG 30E) |
| | |
| | 3B. SUBMIT A DETAIL FOR THE DRINKING FOUNTAIN SHOWING |
| | COMPLIANCE WITH THE FOLLOWING: |
| | A. 11-4.15.2 SPOUT HEIGHT |
| | B. 11-4.15.3 SPOUT LOCATION |
| | C. 11-4.15.5(1) CLEARANCES |
| | D. 11-4.15.5(2) CLEAR FLOOR SPACE |
| | E. 11-4.1.3(10)(A) PROVISIONS FOR THOSE WHO HAVE |
| | DIFFICULTY BENDING OR STOOPING. |
| | |
| | 4B. SUBMIT A DETAIL FOR THE LAVS SHOWING COMPLIANCE |
| | WITH THE FOLLOWING: |
| | A. 11-4.19.2 HEIGHT & CLEARANCES |
| | B. 11-4.19.3 CLEAR FLOOR SPACE |
| | C. 11-4.19.4 EXPOSED PIPES & SURFACES |
| | D. 11-4.19.5 FAUCETS |
| | E. 11-4.19.6 MIRRORS |
| | |
| | 5B. PER SECTION 11-4.22.3 SHOW A 5' TURNING AREA IN THE |
| | TOILET ROOMS. |
| | |
| | 6B. SUBMIT A DETAIL FOR THE SINK SHOWING COMPLIANCE |
| | WITH THE FOLLOWING: |
| | A. 11-4.24.2 HEIGHT |
| | B. 11-4.24.3 KNEE CLEARANCE |
| | C. 11-4.24.4 SINK DEPTH |
| | D. 11-4.24.5 CLEAR FLOOR SPACE - FORWARD APPROACH |
| | REQUIRED MAX 19" UNDERNEATH THE SINK. -CABINET DOORS |
| | ARE NOT ALLOWED. |
| | E. 11-4.24.6 EXPOSED PIPES & SURFACES |
| | F. 11-4.24.7 FAUCETS |
| | |
| | 7B. SUBMIT A PLUMBING FLOOR PLAN INDICATING THE |
| | CONNECTIONS FOR THE SANITARY BUILDING DRAIN AND THE |
| | WATER SERVICE FOR THE ADDITION. SECTION 106.1.2. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | ****NO RESPONSE/NOT ADDRESSED |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 805-6721 |
| | FAX (561) 805-6731 |
| | E-MAIL [email protected] |