| 2007-02-13 06:25:48 | BUILDING PLAN REVIEW | | | PERMIT:07020094 | | | ADD:1101 CHARLES STREET | | | CONT: LANCE H. MOONEY | | | TEL: (561)747-4643 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 1ST | | | ACTION: DENIED | | | | | | 1)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS | | | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS | | | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST | | | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC | | | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES | | | PER 108.3 FBC* | | | | | | 2)) 106.3.3* PRODUCT APPROVALS- 2004 | | | THOSE PRODUCTS THAT ARE RGULATED BY DCA | | | RULE 9B-72 SHALL BE REVIEWED AND | | | APPROVED IN WRITTING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. PROVIDE TWO COPIES OF THE | | | PRODUCT APPROVALS FOR THE NEW DOOR. | | | | | | 3)FBC. 1210.2WALLS WITHIN 2 FEET OF URINALS AND | | | WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT | | | SURFACE, TO A HEIGHT OF 4 FEET ABOVE THE FLOOR, AND | | | EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIALS USED IN | | | SUCH WALLS SHALL BE OF A TYPE THAT IS NOT AVERSELY | | | AFFECTED BY MOISTURE. | | | | | | 4)THE H.C. GRAB BARS ON THE BACK WALL SHALL BE | | | INSTALLED IN ACCORDANCE WITH FBC. CH. 11.FIG30E.THE | | | GRAB BAR ON THE BACK WALL SHALL BE 6 INCHES MAX FROM | | | THE SIDE WALL. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 |
|