| 2007-03-14 19:00:05 | BUILDING REVIEW CHECKLIST: |
| | 1- PROVIDE COMPLETE INFORMATION FOR GENERATOR. |
| | INCLUDING SPECS, CLEARANCES, ETC. . SEC. 106.1.2 CITY |
| | AMENDMENTS TO FBC 2004. |
| | |
| | 2- PROVIDE COMPLETE SPECS FOR BBQ HOOD APPROVED FOR |
| | EXTERIOR LOCATION.SEC. G2447 AND SEC. 106.1.2 CITY |
| | AMENDMENTS TO FBC 2004. |
| | ***NOTE: VERIFY WITH MANUFACTURER SPECS IF LOCATION |
| | NEXT TO WINDOW IS ACCEPTABLE.PROVIDE SPECS. |
| | |
| | 3-BRING DRAWINGS TO PALM BEACH COUNTY. BRING BACK |
| | STAMPED PLANS AND COPY OF THE PAID RECEIPT. |
| | |
| | 4- SHEET A-2:REVISE A/C AREA AND PORCH AREA |
| | CALCULATIONS.BRING PLANS TO PALM BEACH COUNTY FOR |
| | IMPACT FEES ASSESMENT AFTER AREAS ARE REVISED. |
| | |
| | 5- SHEET A-5:REVISE DESIGN PRESSURES FOR WIND LOADS |
| | AT CORNER AREAS. SEE TABLE 1609.6.2.1(2). |
| | |
| | 6- SOIL TEST REPORT NEEDS THE ENGINEERING FIRM |
| | CERTIFICATE OF AUTHORIZATION NUMBER ON EACH SHEET AS |
| | REQUIRED BY SEC. 61G15-23.002 FLORIDA ADMINISTRATIVE |
| | CODE. |
| | |
| | 7- SPECIFY SIZE OF CONTINUOUS ATTIC VENTILATION AS |
| | REQUIRED BY SEC. R806 2004 FLORIDA RESIDENTIAL CODE. |
| | |
| | 8- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE |
| | 9B-72 FOR: |
| | A) HARDI SIDING AND HARDI SOFFIT. |
| | |
| | B) SLIDING GLASS DOORS. |
| | |
| | C) PRECAST LINTELS. |
| | |
| | D) TRUSS CONNECTORS SPECIFIED ON PLANS. |
| | |
| | E) METAL ROOFING.NOA 04-0503.03 SUBMITTED WAS |
| | SUPERSED. SEE COPY OF DADE COUNTY NOA WEBSITE. PROVIDE |
| | CURRENT PRODUCT APPROVAL. |
| | |
| | 9- DESIGNER OF RECORD TO REVIEW AND APPROVE (NOT SIGN |
| | AND SEAL) IN WRITING ALL PRODUCT APPROVALS AS REQUIRED |
| | BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. |
| | |
| | 10- DESIGNER OF RECORD TO SEE PRODUCT APPROVAL FOR |
| | HARDISOFFIT AND SPECIFYHOW THE STRUCTURE WILL BE |
| | REINFORCED TO RECEIVED THIS TYPE OF SOFFIT. SEE TRUSS |
| | SPACING. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. |
| | |
| | 11- SPECIFY SIZE, LOCATION,DESIGN PRESSURESAND |
| | NUMBER OFEXISTING SLIDING GLASS DOORS TO BE REPLACED |
| | AS DESCRIBEDON PERMIT APPLICATION. SEC. 106.1.2 CITY |
| | AMENDMENTS TO FBC 2004. |
| | |
| | 12- SPECIFY ATTIC ACCESS SIZE. SEC. R807 2004 FLORIDA |
| | RESIDENTIAL CODE. |
| | |
| | 13- SHEET A-3: |
| | A) MISSING SHEET A-6 SHOWING DETAILS A/A-6, B/A-6. |
| | |
| | B) ROOFING FRAMING PLAN:SPECIFY CALCULATED UPLIFT |
| | LOADS AT THE ENDS OF PORCH MICROLLAM WHERE SIMPSON |
| | HU410 CONNECTORS WHERE SPECIFIED. SEC. 106.1.2 CITY |
| | AMENDMENTS TO FBC 2004. |
| | |
| | C) ROOF TRUSS DESIGN LOADS CHART IS MISSING THE |
| | ATTIC LIVE LOAD AS REQUIRED BY TABLER301.5 OF 2004 |
| | FLORIDA RESIDENTIAL CODE. |
| | |
| | D) SIMPSON HGA 10 CONNECTOR SPECIFIED ON SECTION |
| | 4/A-3IS A WOOD TO WOOD CONNECTOR. NEED TO SPECIFY |
| | MASONRY CONENCTOR. REVISE AS REQUIRED. |
| | |
| | 14- PROVIDE DRAINAGE PLANS TO SHOW COMPLIANCE WITH SEC. |
| | R401.3 2004 FLORIDA RESIDENTIAL CODE. |
| | |
| | 15- BUILDING IS LOCATED ON FLOOD ZONE A5.NEED TO |
| | SPECIFYFINISH FLOOR ELEVATION AND WILL NEED THE FLOOR |
| | ELEVATION CERTIFICATETO GET FINAL C.O. |
| | |
| | 16- ENERGY CALCULATIONS: |
| | A) MAKE SURE A/C AREA MATCHES REVISED A/C AREA ON |
| | ARCHITECTURAL PLANS. |
| | |
| | B) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM. |
| | |
| | 17- PROVIDE DETAIL/SECTION FOR 2X STRUCTURAL BUCK |
| | DETAIL AS REQUIRED BY SWING DOOR PRODUCT APPROVAL |
| | SUBMITTED.SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. |
| | |