| Plan Review Notes For Permit 07011083 |
| Permit Number |
07011083 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2007-03-19 18:36:25 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBEXISTING BUILDING CODE 2004 | | | FBC R RESIDENTIAL 2004 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | | | | 1.)SE FBC R 301.1, "BUILDINGS AND STRUCTURES, AND ALL | | | PARTS THEREOF, SHALL BE CONSTRUCTED TO SAFELY SUPPORT | | | ALL LOADS . . . INCLUDING WIND LOADS."THE DETAIL | | | PROVIDED IS NOT STRUCTURALLY CONTINUOUS; IT DIVIDES THE | | | WALL INTO TWO PARTS AND DOES NOT ADDRESS HOW THE NEW | | | PARAPET WILL WITHSTAND WIND LOADS.THE DETAIL IS NOT | | | CLEAR; STATES "SPT66 STRAPS AT TOP & BOTTOM OF EACH | | | STUD", AND "STRAPS AT EA STUD TOP & BOTTOM OVER & UNDER | | | PLATES."WHEN RESUBMITTING, INCLUDE THE STRAPS IN THE | | | STRUCTURAL DETAIL. | | | | | | 2.)SPT66 IS FOR 6" FRAMING.2X4 FRAMING IS SHOWN ON | | | YOUR DETAIL.SPT66 DOES NOT PROPERLY ADDRESS ITEM #1. | | | HOWEVER, WHEN REDESIGNING THE WALL DETAIL, PLEASE | | | CONFIRM THAT THE CONNECTORS SPECIFIED ARE THE CORRECT | | | SIZE FOR FRAMING SPECIFIED. | | | |
|