Plan Review Notes
Plan Review Notes For Permit 07010901
Permit Number 07010901
Review Stop B
Sequence Number 2
Notes
Date Text
2007-03-06 16:50:17BUILDING PLAN REVIEW
 PERMIT: 07010901
 ADD: 223 CLEMATIS ST
 CONT: MYRICK ENTERPRISES
 TEL: (954)445-2451
  
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 2ND REVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) COMPLIED.
  
 3) 2ND REQUEST,FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF
 THE COURT.
 NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS
 NOT ACTUALLYCOMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING THEREOF, SUCH NOTICE
 IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 4) 2ND REQUEST, 4) THE PERMIT APPLICATION, DESSCRIPTION
 OF WORK, INDICATES ONLY A INTERIOR DEMOLITION PERMIT
 WHERE AS PLANS INDICATE ADDITIONAL SCOPE OF WORK.
 PLEASE CORRECT THE PERMIT APPLICATION TO INCLUDE THE
 LARGER SCOPE OF WORK.106.1.2*.
  
 5) COMPLIED.
  
 6A) COMPLIED.
  
 6B) COMPLIED.
  
 6C) COMPLIED.
  
 6D) TYPE OF CONSTRUCTION, AS DEFINED IN CHAPTER 3. THIS
 BUILDING IS A TYPE II-B TO BE SPRINKLERED.
 THE OWNERS ARE TAKING THE AREA INCREASES GIVEN TO THEM
 BY THE SPINKLERS.
 THIS MEANS THIS SPACE WILL REQUIRE FIRE SPRINKLERS AND
 FIRE SPRINKLER PLANS.
  
 6ECOMPLIED.
  
 6F) YES A FIRE SPRINKLER WILL BE REQUIRED.
  
 6G-H) COMPLIED.
  
 7) 2ND REQUEST, THE EXITING CONFIGURATION OF THE REAR
 CORRIDOR WILL BE RECONFIGURED TO SOME EXTENT WITH THE
 MODIFICATIONS THAT OF THE REAR EXIT REQUIREMENTS FOR
 THE
 WEST SECOND STORY STAIRWELL ( A COMMON STAIRWELL
 SERVING 2 OR MORE TENANTS) AND VESTIBULE ON THE FIRST
 FLOOR THAT WILL TAKE PLACE. 2004 EXISTING BUILDING CODE
 CHAPTER 8 CHANGE IN OCCUPANCYSEE TABLE 812.4.1.
  
 IFTHERE ARE ANY QUESTIONS PLEASE CALL:
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]