Plan Review Notes
Plan Review Notes For Permit 07010901
Permit Number 07010901
Review Stop B
Sequence Number 1
Notes
Date Text
2007-01-22 08:45:19BUILDING PLAN REVIEW
 PERMIT: 07010901
 ADD: 223 CLEMATIS ST
 CONT: MYRICK ENTERPRISES
 TEL: (954)445-2451
  
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) VALUE FOR THE SCOPE OF WORK IS LOW , PLEASE PROVIDE
 ACURATE VALUE OF
 DESCRIBED WORK OR CITY WILL CALCULATE VALUE OF WORK
 FROM MARSHAL AND SWIFT OR ICC
 VALUES. 108.3* WEST PALM ADMINISTRATIVE CODE.
  
 3 ) ONCE VALUES ARE INCREASED A NOC WILL BE REQUIRED:
 FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF
 THE COURT.
 NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS
 NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE
 RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE:
 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT
 THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 4) THE PERMIT APPLICATION, DESSCRIPTION OF WORK,
 INDICATES ONLY A INTERIOR DEMOLITION PERMI,
 WHERE AS PLANS INDICATE ADDITIONAL SCOPE OF WORK.
 PLEASE CORRECT SO BOTH WILL REFLECT THE TRUE NATURE OF
 THIS PERMIT.
 106.1.2*
  
 5)PLANS, SPECIFICATIONS, REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND
 BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 6)) 110.2* W. P. B. ADMINISTRATIVE
 CODE, INFORMATION THAT IS REQUIRED FOR
 RECORD KEEPING & FOR CERTIFICATE OF
 OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PERMIT WAS ISSUED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) LEVEL OF ALTERATIONS:
 D) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601.
 E) THE DESIGN OCCUPANT LOAD, SEE 1004.
 F) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED, WHETHER THE SPRINKLER SYSTEM
 IS REQUIRED.
 G) ANY SPECIAL STIPULATIONS & CONDITIONS
 OF THE BUILDING PERMIT.
 H) NUMBER OF FLOORS
  
 7) THE EXITING CONFIGURATION OF THE REAR CORRIDOR DOES
 NOT REFLECT WHAT ACTUALLY OCCURS AT THE SITE.
 A NOTE OF CAUTION. THE WEST EXIT OF THE NEWLY EXPANDED
 MONKEY CLUB( IN FOR PERMIT AT THIS TIME) MAY
 CAUSE SOME RECONFIGURATION ON THE FIRST FLOOR TO MEET
 EGRESS REQUIREMENTS, THIS MAY AFFECT YOUR PROJECT.
  
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]