| 2007-09-24 12:31:36 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBCFLORIDA BUILDING CODE 2004 |
| | FBC EBEXISTING BUILDING CODE 2004 |
| | FBC R RESIDENTIAL 2004 |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE |
| | FBC2004 |
| | |
| | FROM PREVIOUS LIST - COMMENTS NOT ADDRESSED, SAME PLAN |
| | DATED 2/28/07 SUBMITTED: |
| | |
| | 1.)PRODUCT APPROVALS ARE TO BE REIVEWED BY DESIGNER |
| | OF RECORD, FBC*106.3.3. |
| | |
| | 2.)THE PLAN SHOWS AN EXISTING WINDOW TO RELOCATE. |
| | WHAT HAPPENS TO THE HOLE IN THE WALL WHERE THE WINDOW |
| | WAS, AND WHERE IS THIS WINDOW GOING?PRODUCT APPROVALS |
| | FOR THE EXISTING WINDOWS ARE REQUIRED IF YOU ARE |
| | REUSING THEM IN ANOTHER LOCATION. |
| | |
| | 3.)ANOTHER BEDROOM STATES "EXISTING WINDOW TO |
| | REMOVE".THIS AREA IS SHOWN GRAPHICALLY AS A WALL.IS |
| | THIS AREA BEING BLOCKED UP?PROVIDE A DETAIL. |
| | |
| | 4.)AS YOU ARE REMOVING WINDOWS, AND IT IS NOT CLEAR |
| | WHICH WINDOWS COMPLIED WITH EMERGENCY EGRESS AT THE |
| | TIME THE HOUSE WAS BUILT, PROVIDE INFORMATION IN |
| | REGARDS TO THE BEDROOM WINDOWS; SIZE, TYPE, OPENING |
| | SIZE, FBC R310.CODE COMPLIANCE CANNOT BE DETERMINED |
| | DUE TO LACK OF INFORMATION. |
| | |
| | 5.)THE DOOR PRODUCT APPROVAL IS FOR A NON IMPACT |
| | DOOR, IMPACT PROTECTION REQUIRED FBC R301.2.1.2. |
| | |
| | 6.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED |
| | IN ADDITION TO THE NOAS SUBMITTED, FAC9B72. |
| | WWW.FLORIDABUILDING.ORG |
| | |
| | 7.)THE APPLICATION DESCRIPTION AND THE PLAN ARE NOT |
| | CONSISTENT IN SCOPE OF WORK.THERE IS NO MENTION OF |
| | THE BEDROOM WINDOWS, REMOVAL OF INTERIOR WALL SHOWN ON |
| | THE PLAN. |
| | |
| | NEW COMMENT: |
| | |
| | 8.)APPLICATION STATES THAT YOU ARE CLOSING IN THE |
| | GARAGE DOOR AND INSTALLING A NEW GARAGE DOOR.THIS IS |
| | NOT REFLECTED ON THE PLAN.THE FLOOR PLAN SHOULD |
| | INDICATE THE LOCATION AND SCOPE OF WORK. |
| | |
| | 9.)THE WALL STUD IS NOT BEARING ON THE SOLE PLATE, |
| | SEE "DOOR OPENNING FRAMING", LEFT SIDE. |
| | |
| | 10.)PROVIDE AN INFILL DETAIL.THE SAME DETAIL CAN BE |
| | USED FOR BOTH THE WINDOW AND GARAGE DOOR OPENINGS. |
| | |
| | 11.)"DOOR OPENNING FRAMING"; IS THIS DETAIL TO BE |
| | USED FOR BOTH THE DOOR AND THE GARAGE DOOR?PLEASE |
| | NOTE ON THE PLAN.IF NOT, PROVIDE A DETAIL FOR THE |
| | OVERHEAD DOOR DETAIL. |
| | |
| | 12.)THE DASHED LINES AT THE OVERHEAD DOOR USUALLY |
| | INDICATE WHERE THE DOOR WILL RETRACT.YOU SHOW THE |
| | DOOR GOING TO THE OUTSIDE OF THE BUILDING; HOW WILL THE |