| Date |
Text |
| 2007-02-26 10:55:13 | BUILDING PLAN REVIEW |
| | PERMIT: 07010734 |
| | ADD:229 SANTA LUCIA DR. |
| | CONT: TREND WEST, INC. |
| | TEL: (561)547-2944 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2006 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW 1ST |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2)PROVIDE A WALL SECTION FRAMING DETAIL OF THE NEW |
| | 2X6 WALL. SHOW THE ELEVATION DRAWINGS WITH THE FRAMING |
| | DETAILS FOR THE DOOR AND WINDOWS OPENINGS. ALSO SHOW |
| | THE CONNECTION OF THE TOP AND BOTTOM PLATES. |
| | |
| | 3)WPB AMENDMENTS 108.3*IF IN THE OPINION OF THE |
| | BUILDING OF THE BUILDING OFFICIAL, THE CLAIMED |
| | VALUATION OF BUILDING, ALTERATION, STRUCTURE, |
| | ELECTRICAL, GAS MECHANICAL OR PLUMBING SYSTEMS APPEARS |
| | TO BE UNDERESTIMATED ON THE APPLICATION, THE PERMIT |
| | SHALL BE DENIED. FOR PERMITTING PURPOSES, VALUATION OF |
| | BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE |
| | TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, |
| | INTERIOR FINISH, ARCHITECTURAL AND DESIGN FEES.OUR |
| | VALUATION REFERENCE IS ICC (BVD), MARSHALL-SWIFT AND |
| | MEANS COST ANALYSIS SERVICES. |
| | |
| | 4)R602.2.3 WOOD STUD WALLS SHALL BE CAPPED WITH A |
| | DOUBLE TOP PLATE INSTALLED TO PROVIDE OVERLAPPING AT |
| | CORNERS AND INTERSECTIONS WITH BEARING PARTITIONS. |
| | PLATES SHALL BE A NOMINAL 2 INCHES IN DEPTH AND HAVE |
| | WIDTH AR LEAST EQUAL TO THE WIDTH OF THE STUDS. |
| | |
| | 5)2004 FL. BLD CODE 1603.1.4 THE |
| | FOLLOWING INFORMATION RELATED TO WIND |
| | SHALL BE SHOWN ON THE CONSTRUCTION |
| | DRAWINGS, |
| | 1)- BASIC WIND SPEED, MPH |
| | 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| | CATEGORY |
| | 3)- WIND EXPOSURE |
| | 4)- INTERNAL PRESSURE COEFFICIENT, |
| | 5)- COMPONENTS & CLADDING, THE DESIGN |
| | WIND PRESSURES IN TERMS OF PSF. |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | 805-6726 |
| | |
| | |
| | |
| | |
| | |