| 2007-04-05 15:39:25 | DENIED BY BUILDING |
| | |
| | 1)104.2.1.3 THE BUILDING OFFICIAL |
| | MAY SET STANDARDS THROUGH DEPARTMENTAL |
| | POLICY STANDARDS FOR PLANS AND SPECIFICATIONS. "NO |
| | WHITE OUT".THE CHANGES THAT WERE MADE ON SHEET G-1 TO |
| | UPDATE THE EDITION OF ASCE 7 ARE NOT ACCEPTABLE. ANY |
| | CHANGES TO SEALED DRAWINGS ARE REQUIRED TO BE MADE BY |
| | THE PERSON THAT SIGNED AND SEALED THOSE DRAWINGS. THE |
| | ITEM THAT IS CHANGED CAN BE CROSSED OUT BY THE |
| | ARCHITECT AND CHANGED BUT " WHITE-OUT" CAN NOT BE USED |
| | OR A NEW CORRECTED SIGNED AND SEALED SHEET CAN BE |
| | SUBMITTED. |
| | |
| | 2)THE RESPONSE TO ITEM NUMBER (4) FROM THE PREVIOUS |
| | REVIEW IS NOT ADEQUATE. 4) PROVIDE A SITE PLAN SHOWING |
| | COMPLIANCE WITH R401.3 DRAINAGE. |
| | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER |
| | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS |
| | TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO |
| | DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE |
| | GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM |
| | OF 6 INCHES (152 MM) WITHIN THE FIRST 10 FEET (3048 |
| | MM). |
| | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER |
| | PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL |
| | WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE |
| | PROVIDED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. |
| | THE SITE PLAN IS REQUIRED TO SHOW THE FALL IN GRADE |
| | AWAY FROM THE STRUCTURE AND THE PATH OF THE SURFACE |
| | WATER TO THE APPROVED COLLECTION POINT. IT IS TO SHOW |
| | ANY SWALES, DRAINS OR OTHER MEANS USED TO CONTAIN THE |
| | SURFACE WATER ON THE LOT WITHOUT DIVERTING IT TO THE |
| | ADJACENT LOTS AND DIRECT IT TO THE APPROVED COLLECTION |
| | POINT. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |