| 2007-04-09 14:43:20 | DENIED BY BUILDING |
| | |
| | 1) THE ENERGY CALCULATION FORM IS REQUIRED TO BE SIGNED |
| | BY THE OWNER/AGENT. SEE FBC CHAPTER 13. |
| | |
| | 2) THERE ARE TWO COLUMNS SPECIFIED ON SHEET A2 OF THE |
| | PLANS. ONE IS ALUMINUM AND THE OTHER IS STEEL. SPECIFY |
| | WHICH ONE WILL BE USED AT THE FRONT ENTRY AND REMOVE |
| | THE OTHER FROM THE PLANS. |
| | |
| | 3)PROVIDE A DETAIL OF THE ALUMINUM COLUMN CAP ON THE |
| | THE ALUMINUM COLUMN AT THE ENTRY PORCH. SPECIFY |
| | THICKNESS, WELDS, DIMENSIONS , UPLIFT CAPACITY, ETC. |
| | SEE ITEM #11 FROM FIRST REVIEW. SEE ITEM 12 OF PREVIOUS |
| | REVIEW. |
| | |
| | 4) SPECIFY THE REQUIRED DEPTH OF EMBEDMENT INTO THE |
| | CONCRETE FOOTING FOR THE ALUMINUM COLUMN ON SHEET A2. |
| | SEE ITEM 13 OF PREVIOUS REVIEW. |
| | |
| | 5)THE TRUSS LAYOUT WAS NOT SUBMITTED. IN ADDITION TO |
| | THE RAISED SEAL THE TRUSS DRAWINGS ARE REQUIRED TO HAVE |
| | THE ORIGINAL WET SIGNATURE OF THE TRUSS ENGINEER. THE |
| | DRAWINGS THAT WERE SUBMITTED HAVE A SIGNATURE STAMP. |
| | SEE FS 471. TRUSS LAYOUT AND DRAWINGS FOR CAN BE GIVEN |
| | TO FIELD INSPECTOR. |
| | |
| | 6) THE TRUSS LAYOUT AND PRODUCT APPROVALS ARE REQUIRED |
| | TO BE REVIEWED AND APPROVED IN WRITING BY THE DESIGNER |
| | OF RECORD FOR THE STRUCTURE. THE DOR FOR THIS PROJECT |
| | IS AN ENGINEER. THE ENGINEER'S SHOP DRAWING REVIEW |
| | STAMP WITH THE REVIEW STATUS INDICATED IS REQUIRED ON |
| | THE THESE ITEMS ALONG WITH HIS SIGNATURE. |
| | |
| | 7) SUBMIT PRODUCT APPROVALS FOR THE EXTERIOR OUTSWING |
| | FRENCH DOOR SHOWN ON THE PLANS AT THE NEW BATHROOM. SEE |
| | ITEM #19 FROM THE PREVIOUS REVIEW. |
| | |
| | 8) SUBMIT PRODUCT APPROVALS FOR STORM PANELS AT THE |
| | FRENCH DOOR IF IT IS NOT IMPACT RESISTANT. |
| | |
| | 9) SPECIFY THE THE FASTENING OPTION THAT WILL BE USED |
| | TO INSTALL THE ASSEMBLY THAT WAS SELECTED ON PAGE 16 OF |
| | THE NOA FOR THE TAMKO MODIFIED ROOFING SYSTEM. SUBMIT |
| | THE RAS 117 CALCULATIONS FOR THE ENHANCED FASTENING |
| | THAT WILL BE REQUIRED AT EDGES AND CORNERS. SEE # 21 ON |
| | PREVIOUS REVIEW. |
| | |
| | 10) THE INFORMATION SUBMITTED FOR THE TRUSS CONNECTORS |
| | AND LINTELS ARE NOT THE PRODUCT APPROVALS. PRODUCT |
| | APPROVALS CAN BE DOWN LOADED FROM THE INTERNET AT |
| | WWW.FLORIDABUILDING.ORG. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)805-6714 |
| | |
| | |
| | |
| | |
| | |
| | |
| | |