Plan Review Notes
Plan Review Notes For Permit 06120598
Permit Number 06120598
Review Stop P
Sequence Number 1
Notes
Date Text
2007-01-09 16:57:14DENIED
 REFERENCE: FBC-2004 PLUMBING AND FBC-2004 CHAPTER 1
  
 THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING
 PLAN REVIEW IN ORDER TO MEET CODE COMPLIANCE. PLEASE
 SUBMIT PLUMBING PLANS FOR REVIEW INDICATING THE SCOPE
 OF WORK TO BE DONE PER THE FOLLOWING:
  
 1. PER FBC-2004 CHAPTER 1 SECTION 106.3.5.4 RESIDENTIAL
 (ONE AND TWO
 FAMILY) SUBMIT A PLUMBING SANITARY
 ISOMETRIC RISER DIAGRAM INDICATING ALL
 WASTE, VENTS, TRAPS WITH SIZES, AND
 CLEANOUT LOCATIONS FOR THE NEW PROPOSED PLUMBING
 INDICATED ON SHEET A-1.
 NOTE: IMPORTANT INFORMATION FOR NEW LAUNDRY PER
 FBC-2004 PLUMBING.
 (A) SECTION 406.3 WASTE CONNECTIONS.THE TRAP AND
 FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES
 WASHER SHALL BE A MINIMUM OF 2 INCHES
 (51MM) IN DIAMETER. THE AUTOMATIC
 CLOTHES WASHER FIXTURE DRAIN SHALL
 CONNECT TO A BRANCH DRAIN OR DRAINAGE
 STACK A MINIMUM OF 3 INCHES (76MM) IN
 DIAMETER.
 (B) 802.4 STANDPIPES.STANDPIPES SHALL BE INDIVIDUALLY
 TRAPPED. STANDPIPES SHALL
 EXTEND A MINIMUM OF 18 INCHES (457MM)
 AND A MAXIMUM OF 42 INCHES (1066MM)
 ABOVE THE TRAP WEIR. ACCESS SHALL BE
 PROVIDED TO ALL STANDPIPES AND DRAINS
 FOR RODDING.PLEASE INDICATE STANDPIPES ON RESUBMITTAL.
 NOTE: PLEASE INDICATE STANDPIPES ON DRAWING.
 (C) 708.9 ACCESS. ACCESS SHALL BE
 PROVIDED TO ALL CLEANOUTS. PLEASE INDICATE THE CLEANOUT
 FOR WASHING MACHINNE AT FOUR FEET ABOVE FINNISH FLOOR
 (4' A.F.F.)
  
 2. SHEET A-4 INDICATES NEW DOWNSPOUTS AND SCUPPERS:
 PLEASE PROVIDE THE FOLLOWING INFORMATION.
 A} DETAIL OF ROOF INDICATING SQUARE FOOTAGE OF ROOF AND
 VERTICAL WALLS DRAINING TO DOWNSPOUTS AND SCUPPERS TO
 VERIFY COMPLIANCE WITH FBC-2004 PLUMBING SECTIONS
 1106.2 VERTICAL CONDUCTORS AND LEADERS, 1106.4 VERTICAL
 WALLS, 1106.7 SCUPPERS, AND 1107.2 SEPERATE SYSTEMS
 REQUIRED.
  
 3. SHEET A-7 SCUPPER HEAD AND LEADER DETAIL: ONE PART
 OF THE DETAIL INDICATES A 4" X 4" GALV. MET. DOWN
 LEADER, AND ANOTHER PART OF THE DETAIL INDICATES LEADER
 BEING 8", PLEASE CORRELATE THIS DETAIL FOR THE
 RESUBMITTAL SIZING THEM WITH THE TABLES FROM COMMENT
 #2.
  
 4. SHEET A-7 SCUPPER HEAD AND LEADER DETAIL: DETAIL
 FAILS TO INDICATE SIZE OF SCUPPERS PER FBC-2004
 PLUMBING SEC.1106.7, AND THERE IS NOT A DETAIL OF THE
 SECONDARY ROOF DRAIN SYSTEM PER FBC-2004 PLUMBING, SEC.
 1107.2. PLEASE REVISE THE DETAIL FOR THE RESUBMITTAL.
  
 ************IMPORTANT INFORMATION
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
  
 END OF COMMENTS:
  