| 2007-01-08 14:06:33 | BUILDING PLAN REVIEW |
| | PERMIT: 06120592 |
| | ADD: 444 W RAILROAD AVESUITE 450 |
| | CONT: PBM DEVELOPMENT |
| | TEL: (561)368-2544 |
| | |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1STREVIEW |
| | ACTION: DENIED |
| | |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) PBM DEVELOPMENT, INC. ACTING AS AN ARCHITECTURAL |
| | FIRM MUST AQUIRE A CERTIFICATE OF AUTHORIZATION. |
| | 481.219 F.S.CERTIFICATE OF |
| | AUTHORIZATION.THE TITLE BLOCK FOR ANY |
| | SHEET BEARING THE NAME OF AN ARCHITECT |
| | PRACTICING UNDER A FICTITIOUS NAME, A |
| | CORPORATION, OR A PARTNERSHIP, OFFERING ARCHITECTURAL |
| | SERVICES, SHALL INCLUDE |
| | THE CERTIFICATE OF AUTHORIZATION |
| | NUMBER.ADD THE NUMBER TO EACH SHEET. |
| | THIS MAY BE ADDED BY HAND. |
| | |
| | 3) THE TITLEBLOCK IS MISSING THE LOCATION OF |
| | THE JOB, ONLY THE SUITE NUMBER HAS BEEN |
| | PROVIDED. SEE FL S S 61G1-16.004 TITLE BLOCK(3) |
| | IDENTIFICATIOJN OF PROPERTY. |
| | |
| | 4) SHEET A-03106.1.2 ADDITIONAL INFORMATION REQUIRED. |
| | THE |
| | FLOOR PLAN DOESN'T INDICATE DOOR SWINGS WITHIN THE |
| | UNIT. |
| | IT APPEARS CONFERENCE ROOM 454 MAY HAVE A |
| | PAIR OF 30" DOORS. SEE SECTION 11-4.13.4 DOUBLE-LEAF |
| | DOORWAYS. |
| | IF DOORWAYS HAVE TWO INDEPENDENTLY OPERATED DOOR |
| | LEAVES, |
| | THEN AT LEAST ONE LEAF SHALL MEET THE SPECIFICATIONS |
| | IN |
| | SECTION 11-4.13.5 AND SECTION 11-4.13.6 . THAT LEAF |
| | SHALL BE AN ACTIVE LEAF. |
| | |
| | 5)SHEET A-04 IS MISSING EMERGENCY LIGHTING |
| | REQUIREMENTS SEE TABLE |
| | 1006, BUSINESS > 2 STORIES ABOVE GRADE LED |
| | |
| | 6) SHEET A-04 1006.3.1 |
| | EXITS SHALL BE MARKED BY AN APPROVED SIGN READILY |
| | VISIBLE FROM ANY |
| | DIRECTION OF EXIT ACCESS. EVERY EXIT SIGN SHALL BE |
| | SUITABLY ILLUMINATED |
| | BY A RELIABLE LIGHT SOURCE. EXTERNALLY AND INTERNALLY |
| | ILLUMINATED SIGNS |
| | SHALL BE VISIBLE IN BOTH NORMAL AND EMERGENCY |
| | LIGHTING. |
| | |
| | |
| | 7) SHEET A-05 & A-06 BOTH INDICATE CHAIR RAIL AND CROWN |
| | TRIM, BUT NO MENTION AS TO TYPE OF MATERIAL. 805.3 FOAM |
| | PLASTIC USED AS TRIM IN ANY OCCUPANCY SHALL |
| | |
| | COMPLY WITH SECTION 2604.2 . 2604.2 INTERIOR TRIM. FOAM |
| | PLASTIC USED AS INTERIOR TRIM SHALL COMPLY WITH |
| | SECTIONS 2604.2.1 THROUGH 2604.2.4 . |
| | 2604.2.1 DENSITY. |
| | THE MINIMUM DENSITY OF THE INTERIOR TRIM SHALL BE 20 |
| | PCF (320 KG/M 3 ). |
| | 2604.2.2 THICKNESS. |
| | THE MAXIMUM THICKNESS OF THE INTERIOR TRIM SHALL BE 0.5 |
| | INCH (12.7 MM) AND THE MAXIMUM WIDTH SHALL BE 8 INCHES |
| | (204 MM). |
| | 2604.2.3 AREA LIMITATION. |
| | THE INTERIOR TRIM SHALL NOT CONSTITUTE MORE THAN 10 |
| | PERCENT OF THE AGGREGATE WALL AND CEILING AREA OF ANY |
| | ROOM OR SPACE. |
| | 2604.2.4 FLAME SPREAD. |
| | THE FLAME SPREAD INDEX SHALL NOT EXCEED 75 WHERE TESTED |
| | IN ACCORDANCE WITH ASTM E 84. THE SMOKE-DEVELOPED INDEX |
| | SHALL NOT BE LIMITED. |
| | |
| | 8) SHEETS A-05 & A-06 BOTH ALSO INDICATE THE USE OF |
| | GLAZING NEXT TO DOORWAYS, PLANS DO NOT INDICATE WHAT |
| | TYPE OF GLAZING SHALL BE USED. |
| | 2406.3 HAZARDOUS LOCATIONS. |
| | THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS |
| | LOCATIONS REQUIRING SAFETY GLAZING MATERIALS: |
| | 1.GLAZING IN SWINGING DOORS EXCEPT JALOUSIES (SEE |
| | SECTION 2406.3.1 ). |
| | 2.GLAZING IN FIXED AND SLIDING PANELS OF SLIDING |
| | DOOR ASSEMBLIES AND PANELS IN SLIDING AND BIFOLD CLOSET |
| | DOOR ASSEMBLIES. |
| | 3.GLAZING IN STORM DOORS. |
| | 4.GLAZING IN UNFRAMED SWINGING DOORS. |
| | 5.GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, |
| | WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS. |
| | GLAZING IN ANY PORTION OF A BUILDING WALL ENCLOSING |
| | THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE |
| | GLAZING IS LESS THAN 60 INCHES (1524 MM) ABOVE A |
| | STANDING SURFACE. |
| | 6.GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL |
| | ADJACENT TO A DOOR WHERE THE NEAREST EXPOSED EDGE OF |
| | THE GLAZING IS WITHIN A 24-INCH (610 MM) ARC OF EITHER |
| | VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND |
| | WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS |
| | THAN 60 INCHES (1524 MM) ABOVE THE WALKING SURFACE. |
| | |
| | 9) A-06 INDICATES THE USE OF A BREAKROOM SINK, NO |
| | ACCESSIBILITY. |
| | SINKS: |
| | 11-4.24.2 SINKS, HEIGHT. SINKS SHALL |
| | BE MOUNTED WITH THE COUNTER NO HIGHER |
| | THAN 34" ABOVE THE FINISH FLOOR. |
| | 11-4.24.3 KNEE CLEARANCE THAT IS AT |
| | LEAST 27" HIGH 30" WIDE, AND 19" DEEP |
| | SHALL BE PROVIDED UNDERNEATH SINKS. |
| | 11-4.24.5 CLEAR FLOOR SPACE. |
| | A CLEAR FLOOR SPACE AT LEAST 30 INCHES BY 48 INCHES |
| | (760 MM BY 1219 MM) COMPLYING WITH SECTION 11-4.2.4 |
| | SHALL BE PROVIDED IN FRONT OF A SINK TO ALLOW FORWARD |
| | APPROACH. THE CLEAR FLOOR SPACE SHALL BE ON AN |
| | ACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM OF 19 |
| | INCHES (485 MM) UNDERNEATH THE SINK |
| | |
| | BUILDING PLAN REVIEW |