| 2007-02-05 17:34:42 | DENIED |
| | REFERENCE: FBC-2004 PLUMBING |
| | FBC-2004 CHAPTER 1 |
| | FBC-2004 CHAPTER 11 |
| | |
| | 1. SUBMIT AN EXISTING FLOOR PLAN SHOWING THE EXTENT OF |
| | THE DEMOLITION.SECTION 106.1 |
| | |
| | 2. INDICATE THE OCCUPANCE OF THE SPACE SO THAT MINIMUM |
| | FACILITIES CAN BE DETERMINED. TABEL 403.1. |
| | |
| | 3. SHT 1 TOILET ROOM SHALL BE ACCESSIBLE. SHOW THE |
| | FOLLOWING: |
| | A. 11-4.16.2 CLEAR FLOOR SPACE |
| | B. 11-4.16.5 FLUSH CONTROLS |
| | C. 11-4.19.2 HEIGHT & CLEARANCES |
| | D. 11-4.19.3 CLEAR FLOOR SPACE |
| | E. 11-4.19.4 EXPOSED PIPES & SURFACES |
| | F. 11-4.19.5 FAUCETS |
| | |
| | 4. THE WATER CLOSET SHALL BE 18" OFF THE WALL TO THE |
| | CENTERLINE OF THE FIXTURE. (FIG. 28). |
| | |
| | 5. THE LAV SHALL BE A MINIMUM 15" OFF THE WALL TO THE |
| | CENTERLINE OF THE FIXTURE. (30" MINIMUM BETWEEN THE |
| | CENTERLINE OF THE W/C TO THE CENTERLINE OF THE LAV.). |
| | SECTION 405.3.1. |
| | |
| | 6. THE TOILET ROOM SHALL SHOW AN UNOBSTRUCTED TURNING |
| | AREA. SECTION 11-4.22.3. |
| | |
| | 7. THE TOILET ROOM DOOR SHALL NOT SWING INTO THE FLOOR |
| | SPACE REQUIRED FOR ANY DIXTURE. SECTION 11-4.23.2. |
| | |
| | 8. TABLE 403.1 A DRINKING FOUNTAIN IS REQUIRED, AND |
| | DEPENDING ON THE OCCUPANCY, A SERVICE SINK MAY BE |
| | REQUIRED. |
| | |
| | 9. SUBMIT A SANITARY RISER DIAGRAM. SHOW ALL PIPE |
| | SIZES, TRAPS AND VENTS. SECTION 106.3.5.1.3 |
| | |
| | 10. SUBMIT A WATER RISER DIAGRAM. SHOW ALL PIPE SIZES, |
| | VALVES, AND, IF REQUIRED, WATER HAMMER ARRESTORS. |
| | SECTIONS 106.3.5.1.3 & 604.9. |
| | |
| | 11. THE WALLS OF ALL PUBLIC RESTROOMS SHAL BE SMOOTH, |
| | HARD & NONABSORBENT. SECTION 1210.2PLEASE SUBMIT A |
| | FINISH SCHEDULE INDICATING THE FINISH OF THE RESTROOM. |
| | SECTION 106.1.1. |
| | |