Plan Review Notes
Plan Review Notes For Permit 06120446
Permit Number 06120446
Review Stop B
Sequence Number 2
Notes
Date Text
2007-08-16 10:57:552004 FBC
 ENCLOSE CARPORT TO FLORIDA ROOM
  
 DENIED BY BUILDING
  
 1) THE NOTICE OF COMMENCEMENT HAS EXPIRED AND WILL BE
 NEED TO BE RE-RECORDED BEFORE THE PERMIT IS ISSUED.
 THIS CAN BE DONE AFTER THE PLANS HAVE BEEN APPROVED BY
 ALL THE TRADES.
 THE WORK ON THE PROJECT IS REQUIRED TO START WITHIN 90
 DAYS OF THE DATE THE PERMIT IS ISSUED.
  
 2) BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY.THE PLANS MUST BE
 STAMPED AND THE RECEIPT ATTACHED TO THE APPLICATION.
 233-5025 IS THE CO. IMPACT FEE DEPARTMENT'S NUMBER.
  
 3) SHOW COMPLIANCE WITH FBC R 302.1 AND 302.2 FROM
 COMMENTS NUMBER 3 AND 4 OF THE PREVIOUS REVIEW. SPECIFY
 ON THE SITE PLAN ON SHEET 2 THAT THERE ARE NO
 STRUCTURES WITHIN 6' OF THE CARPORT ON THE ADJACENT LOT
 AT THE SIDE WITH THE 4' 7-1/2 " DISTANCE TO THE
 PROPERTY LINE OR SPECIFY ONE HOUR FIRE RATED WALLS WITH
 NO OPENINGS.
  
 4) SHOW COMPLIANCE WITH R403.1.4 WHICH REQUIRES ALL
 EXTERIOR FOOTINGS TO BE A MINIMUM OF 12 INCHES BELOW
 GRADE.
  
 5) SHOW COMPLIANCE WITH R404.1.6 WHICH REQUIRES THE
 CONCRETE FOUNDATION WALL TO EXTEND 6 INCHES ABOVE ABOVE
 THE ADJACENT FINISH GRADE.
  
 6) SHOW COMPLIANCE WITH FBC RESIDENTIAL SECTION 704,
 WHICH REQUIRES A MINIMUM 6 INCH INSPECTION SPACE
 BETWEEN THE FINISH GRADE AND THE EXTERIOR STUCCO
 VENEER. THE EXCEPTIONS ALLOW A 4 INCH INSPECTION SPACE
 ABOVE PATIO SLABS AND ENTRY AREAS.
  
 7) SPECIFY THE PROPOSED FINISH FLOOR ELEVATION AT THE
 ENCLOSED CARPORT AND THE EXISTING RESIDENCE. FBC*
 106.1.2
  
 8) IF VAPOR RETARDER REQUIRED BY R506.2.3 CAN NOT BE
 INSTALLED, THE SLAB WILL BE REQUIRED TO BE TREATED WITH
 A WATERPROOF SEALER.
  
 9) THE ENERGY CALCULATION FORM IS REQUIRED TO BE SIGNED
 BY THE OWNER/AGENT PER FBC CHAPTER 13.
  
 10) THE WALL SECTIONS ON SHEET 4 SPECIFIES R-30
 INSULATION BETWEEN THE 2 X 6 ROOF JOISTS. THE R-VALUE
 FOR 5-1/2" INSULATION IS R-19. PLEASE REVISE THE WALL
 SECTIONS AND THE ENERGY CALC. FORM FOR THE SINGLE
 ASSEMBLY FRAME CEILING.
  
 11)WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 - ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]
  
  
  
  