| 2007-01-10 07:53:59 | DENIED; | | | PLANS DO NOT HAVE ENOUGH INFORMATION TO DO A DEMO | | | REVIEW. THIS WAS A BEGAL SHOP THAT SERVED MEALS. | | | PLUMBING DEMO MUST BE DONE BY A LICENSED PLUMBING | | | CONTRACTOR, PERMIT AND INSPECTION REQUIRED. HEAT HOOD | | | FOR THE BEGAL OVEN, OVEN AND GAS TO OVEN IS NOT SHOWN. | | | HOOD FOR KITCHEN COOKING EQUIPMENT, AND GAS TO THE | | | EQUIPMENT. WILL ALL THIS EQUIPMENT BE DEMOED OR RE-USED | | | PLEASE SHOW ON PLANS. ALL GAS PIPING MUST BE REMOVED | | | BACK TO THE GAS METER. IS GREASE TRAP TO BE RE-USED ? | | | ALL GREASE WASTE LINES AND SANITARY PIPE THAT WILL NOT | | | BE RE-USED CANNOT HAVE ANY DEAD ENDS SEE FBC-2004 | | | PLUMBING SECTION 704.5. | | | PLUMBING & GAS PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|