| 2007-08-30 12:10:19 | DENIED |
| | REFERENCE: FBC-2004 PLUMBING |
| | FBC-2004 BUILDING |
| | FBC-2004 CHAPTER 1 |
| | |
| | ****FROM PREVIOUS REVIEW: COMMENT NUMBER TO REMAIN THE |
| | SAME. |
| | |
| | 1. SHT A-2 MORE INFORMATION REQUIRED. NOTE INDICATES A |
| | VENT WILL BE REMOVED. PLEASE INDICATE WHAT TYPE OF VENT |
| | WILL BE REMOVED.--NOTE INDICATES THAT THE ROOF |
| | DRAIN WILL NEED AN EXTENTION. IF OLD PAVERS WILL BE |
| | REMOVED FROM THE ROOF AND NEW PAVERS WILL BE INSTALLED, |
| | WILL THE NEW PAVERS BE THICKER THE THOSE REMOVED? THE |
| | ROOF SHOWS NO SECONDARY ROOF DRAINS. PLEASE INDICATE |
| | THE SQUARE FOOTAGE BEING DRAINED BY THIS ROOF DRAIN. |
| | INCLUDE 1/2 AREA OF ALL VERTICAL WALLS, AND THE AREA |
| | FROM THE ROOF ABOVE DRAINING ON TO THE ROOF AREA. (A |
| | DOWNSPOUT IS INDICATED). SHOW THE LOCATION OF ALL ROOF |
| | DRAINS AND SECONDARY ROOF DRAINS OR SCUPPERS IN ROOF |
| | AREA WHERE NEW TILE WORK WILL BE INSTALLED. SECTIONS |
| | 106, 1107 AND ALL SUBSECTIONS& 106.1.1 1. |
| | ****RESPONSE,VENT ISSUE NOT ADDRESSED |
| | |
| | 2. OK |
| | |
| | 3. SHT M-1 INDICATES HOT & COLD WATER TO BE STUBBED OUT |
| | FOR FUTURE USE. ALSO THIS SHEET SHOWS (4) 4" RAIN WATER |
| | LEADERSTO BE REUSED.A PLUMBING PERMIT WILL BE |
| | REQUIRED. SECTION 105.1. |
| | ****RESPONSE NOTED. |
| | 4. OK |
| | |
| | **********NEW COMMENT********** |
| | |
| | 1B. WHEN RESUBMITTING PLANS PLEASE INDICATE CORRECTIONS |
| | BY CLOUDING CORRECTIONS AND/OR DELETIONS.--REMOVE |
| | ALL OLD SHEET TO BE REPLACED WITH REVISIED SHEETS AND |
| | SUBMIT ALL OLD SHEETS SEPARATELY. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 805-6721 |
| | FAX (561) 805-6731 |
| | E-MAIL [email protected] |