2007-02-23 12:19:44BUILDING PLAN REVIEW
 PERMIT: 06120362
 ADDRESS: 206 S OLIVE/ 120 S OLIVE
 CONT: L. DAVIS
 TEL: (561)718-8161
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) DESCREPANCY PLEASE CORRECT THE ADDRESS OF THE
 JOBSITE,SEE PERMIT APPLICATION VS PLANS.
 106.1.2*ADDITIONAL INFORMATION REQUIRED.
 2A) THIS SITE APPEARS TO BE A OFFICE CONDOMINIUM
 SITE.THE APPLICATION INDICATES A UNIT ON THE FIRST
 FLOOR BY THE PCN USED.
 2B) THE PLANS INDICATE WORK ON THE 7TH AND 8TH FLOOR
 WHERE AS THE PALM BEACH COUNTY PROPERTY APPRAISERS
 OFFICE DOES NOT REFLECT ANY PROPERTY CONTROL NUMBERS ON
 THE 8TH FLOOR. IF THESE NEW STAIRS ARE GOING TO THE 8TH
 FLOOR THIS SQUARE FOOTAGE ON THE EIGTH FLOOR WOULD HAVE
 A SEPERATE PROPERTY CONTROL NUMBER UNLESS THIS IS
 CONSIDERD COMMON AREAS TO ALL TENANTS, SUCH AS
 RESTROOMS AND OR AN ASSOCATION OWNED SUITE OR OFFICE.
 PLEASE PROVIDE DOCUMENTATION OF OWNERSHIP.
 A UNITY OF TITLE MAY BE REQUIRED.
  
 3) THE COVERSHEET, LS-1 NOR THE STRUCTURAL SHEETS
 PROVIDE THE FOLLOWING INFORMATION:
 110.2* W. P. B. ADMINISTRATIVE
 CODE, INFORMATION THAT IS REQUIRED FOR
 RECORD KEEPING & FOR CERTIFICATE OF
 OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PERMIT WILL BE ISSUED.
 PLEASE PROVIDE THE LEVEL OF ALTERATION LISTED UNDER
 THE 2004 EXISTING BUILDING CODE.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601.
 D) THE OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED, WHETHER THE SPRINKLER SYSTEM
 IS REQUIRED.
 F) ANY SPECIAL STIPULATIONS & CONDITIONS
 OF THE BUILDING PERMIT.
 G) SQ. FT. 8TH FLOOR BEING REBUILT
 H) SQ. FT. FOOTPRINT BUILDING
 I ) SQ. FT. UNDER ROOF (TOTAL)
  
 4) THE PLANS APPEAR TO INCORPORATE A LARGER SCOPE OF
 WORK THAN LISTED ON THE DESCRIPTION OF WORK LISTED IN
 THE PERMIT APPLICATION.
 IT APPEARS THE 8TH FLOOR IS BEING REBUILT. WITH THE
 STEEL COLUMNS AND FRAMING SHOWN ON S-2 IF SO PLEASE
 INDICATE ON THE PERMIT APPLICATION DESCRIPTION OF
 PROJECT.
  
 5) NOTE: WITH THE ANSWER TO 3B USE AND OCCUPANCY NOT
 KNOWN THIS REVIEW WILL BE ASSUMING THIS TO BE A
 BUSINESS OCCUPNCY FOR THE PARAMETERS OF THIS REVIEW.
  
 6)IN AS SUCH THE REVIEW AND INSPECTION AND ISSUANCE
 OF THE CERTIFICAT OF OPERATION WILL BE ISSUED BY THE
 DEPARTMENT WHICH INDICATES THAT THE CONVEYANCE HAS HAD
 THE REQUIRED SAFETY INSPECTION AND TEST AND THE FEES
 HAVE BEEN PAID AS PROVIDED IN THIS CHAPTER 399 FS.
  
 7A) IT APPEARS THE EXTERIOR WALLS ARE TERRA-COTTA AND A
 NEW STEEL INNER FRAME-WORK IS BEING ADDED. SHEE A-4
 INDICATES A WINDOW INSTALLATION WITH BUCK BUT THIS
 DETAIL
 IF TAKEN LITTERALY MEANS THAT THE WINDOW AND BUCK WILL
 BE ATTACHED TO THE TERRA-COTTA WALL AND NOT THE
 STRUCTURAL STEEL FRAME WORK.
  
 7B)IF THE WINDOW DETAIL IS REVISED TO BE SECURED TO
 THE STRUCTURAL STEEL FRAMEWORK PLEASE PROVIDE WHAT WILL
 SEAL WEATHER FROM THE JOINT BETWEEN THE TERRA-COTTA AND
 THE
 STEEL FRAME?
  
 7C) SHEET A-4 WINDOW DETAIL INDICATES A WOOD BUCKPLEASE
 SEE COMPLIANCE COMMENTS,1714.5.4.2 MASONRY, CONCRETE
 OR OTHER STRUCTURAL SUBSTRATE.
 WHERE THE WOOD SHIM OR BUCK THICKNESS IS LESS THAN 1 1
 / 2 INCHES (38 MM), WINDOW AND DOOR ASSEMBLIES SHALL BE
 ANCHORED THROUGH THE MAIN FRAME OR BY JAMB CLIP OR
 SUBFRAME SYSTEM, IN ACCORDANCE WITH THE MANUFACTURER'S
 PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE
 SECURELY FASTENED DIRECTLY INTO THE MASONRY, CONCRETE
 OR OTHER STRUCTURAL SUBSTRATE MATERIAL. UNLESS
 OTHERWISE TESTED, BUCKS SHALL EXTEND BEYOND THE
 INTERIOR FACE OF THE WINDOW OR DOOR FRAME SUCH THAT
 FULL SUPPORT OF THE FRAME IS PROVIDED. SHIMS SHALL BE
 MADE FROM MATERIALS CAPABLE OF SUSTAINING APPLICABLE
 LOADS, LOCATED AND APPLIED IN A THICKNESS CAPABLE OF
 SUSTAINING APPLICABLE LOADS. ANCHORS SHALL BE PROVIDED
 TO TRANSFER LOAD FROM THE WINDOW OR DOOR FRAME TO THE
 ROUGH OPENING SUBSTRATE.
  
 8)SHEET A-4 STAIR DETAIL, INDICATES THE RISERS TO BE
 7.5" AND THE TTREADS TO BE 10". 1009.3 STAIR TREADS AND
 RISERS. STAIR RISER HEIGHTS SHALL BE 7 INCHES (178 MM)
 MAXIMUM AND 4 INCHES (102 MM) MINIMUM. STAIR TREAD
 DEPTHS SHALL BE 11 INCHES (279 MM) MINIMUM.
  
 9) SHEET A-5 HANDRAIL DETAIL# 6, INDICATES 2" BETWEEN
 THE HANDRAIL AND WALL.11-4.9.4(3) THE CLEAR SPACE
 BETWEEN HANDRAILS AND THE WALL SHALL BE 1 1/2".
  
 10) SHEET A-5 WHITE-OUT ON DETAIL "A" - R-19
 104.2.1.3 THE BUILDING OFFICIAL
 MAY SET STANDARDS THROUGH DEPARTMENTAL
 POLICY STANDARDS FOR PLANS AND SPRCIFICA
 TIONS. "NO WHITE OUT".
  
 11)1609.1.4 PROTECTION OF OPENINGS.
 IN WIND-BORNE DEBRIS REGIONS, EXTERIOR
 GLAZING THAT RECEIVES POSITIVE PRESSURE
 IN THE LOWER 60 FEET (18.3 M) IN
 BUILDINGS SHALL BE ASSUMED TO BE
 OPENINGS AND THE BALANCE OF GLAZED
 OPENINGS IN THE REST OF THE BUILDING
 SHALL BE ASSUMED TO BE ZERO UNLESS SUCH
 GLAZING THAT RECEIVES POSITIVE PRESSURE
 IS IMPACT RESISTANT OR PROTECTED WITH AN
 IMPACT RESISTANT COVERING MEETING THE
 REQUIREMENTS OF SSTD 12, ASTM E 1886 AND
 ASTM E 1996, OR MIAMI-DADE TAS 201, 202
 AND 203 REFERENCED THEREIN AS FOLLOWS:
 1.GLAZED OPENINGS LOCATED WITHIN 30
 FEET (9.1 M) OF GRADE SHALL MEET THE
 REQUIREMENTS OF THE LARGE MISSILE TEST.
 2.GLAZED OPENINGS LOCATED MORE THAN
 30 FEET (9.1 M) ABOVE GRADE SHALL MEET
 THE PROVISIONS OF THE SMALL MISSILE
 TEST.
  
 12)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 13) WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 14)FL BLD CODE 1609.1.4: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) GLAZED WINDOWS
 B) GLAZED DOORS
 C) HOLLOW METAL DOORS
 D) MULLIONS
 E) ROOFING ASSEMBLIES
  
 15)FL S. S. 553.71(7) " THRESHOLD
 BUILDING" MEANING ANY BUILDING WHICH IS
 GREATER THAN (3) STORIES OR 50 FT IN
 HEIGHT, OR WHICH HAS AN ASSEMBLY OCCUPAN
 CY CLASSIFICATION AS DEINED IN THE
 FLORIDA BUILDING CODE WHICH EXCEEDS
 5,000 SQ FT IN AREA AND AN OCCUPANT
 CONTENT OF GREATER THAN 500 PERSONS.
 105.13.1 THE ENFORCING AGENCY SHALL
 REQUIRE A SPECIAL INSPECTOR TO PERFORM
 STRUCTURAL INSPECTIONS ON A THRESHOLD
 BUILDING PURSUANT TO A STRUCTURAL
 INSPECTION PLAN PREPARED BY THE
 ENGINEER OF RECORD. THE STRUCTURAL
 INSPECTION PLAN MUST BE SUBMITTED TO THE
 ENFORCING AGENCY PRIOR TO THE ISSUANCE
 OF A BUILDING PERMIT FOR THE
 CONSTRUCTION OF A THRESHOLD BUILDING.
 THE PURPOSE OF THE STRUCTURL INSPECTION
 PLAN IS TO PROVIDE SPECIFIC INSPECTION
 PROCEDURES AND SCHEDULES SO THAT THE
 BUILDING CAN BE ADEQUATELY INSPECTED FOR
 COMPLIANCE WITH THE PERMITTED DOCUMENTS.
  
 16)W.P.B. AMENDMENT 105.13.4.4 ALL
 PLANS FOR THE BUILDING WHICH ARE
 REQUIRED TO BE SIGNED AND SEALED BY THE
 ARCHITECT OR ENGINEER OF RECORD CON-
 TAIN A STATEMENT THAT, TO THE BEST OF
 THE ARCHITECT'S PR ENGINEER'S KNOWLEDGE,
 THE PLANS AND SPECIFICATIONS COMPLY WITH
 THE APPLICABLE FIRE-SAFETY STANDARDS AS
 DETERMINED BY THE LOCAL AUTHORITY IN
 ACCORDANCE WITH THIS SECTION AND 633
 FLORIDA STATUTE.
  
 17)WPB AMENDMENT 105.13.6. W.P.B.
 CONSTRUCTION SERVICES DEPARTMENT
 REQUEST FOR THRESHOLD BUILDINGS A
 SPECIAL INSPECTOR AS REQUIRED BY S.
 553.79(5) FLORIDA STATUTES TO THE MIN-
 IMUM INSPECTIONS REQUIRED BY THIS CODE.
 CONTACT HAROLD PISKURA MANAGER OF THE
 SPECIAL INSPECTOR PROGRAM AT (561)
 805-6711 FOR FURTHER INFORMATION BEFORE
 THE PERMIT MAY BE ISSUED.
  
 18) BUILDING PROVISO:
 ) 109.3.10.1 HURICANE PROTECTION.
 IT SHALL BE UNLAWFUL FOR ANY PERSON TO
 ALLOW CONSTRUCTION RELATED MATERIALS
 EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR
 OTHERWISE UNSECURED AT A CONSTRUCTION
 SITE FROM 24 HRS. AFTER A HURRICANE
 WATCH HAS BEEN ISSUED UNTIL THE
 HURRICANE WATCH OR WARNING HAS BEEN
 LIFTED. ALL SUCH CONSTRUCTION MATERIALS,
 EQUIPMENT AND DEBRIS SHALL BE EITHER
 REMOVED FROM THE CONSTRUCTION SITE OR
 SECURED IN SUCH A MANNER AS TO MINIMIZE
 THE DANGER OF SUCH CONSTRUCTION
 MATERIALS, EQUIPMENT AND DEBRIS CAUSING
 DAMAGE TO PERSONS OR PROPERTY FROM HIGH
 WINDS.
 ANY PERSONS WHO FAILS TO COMPLY TO
 REMOVE OR SECURE THE CONSTRUCTION
 MATERIALS EQUIPMENT AND DEBRIS WITHIN
 24 HRS AFTER A HURRICANE WATCH HAS BEEN
 ISSUED SHALL BE SUBJECT TO A FINE NOT TO
 EXCEED $500.00.
 IN ADDITION TO THE ABOVE, A LICENSED
 CONTRACTOR WHO VIOLATES THIS SECTION
 SHALL BE SUBJECT TO DISCIPLINE PURSUANT
 TO SECTION 113 OF THIS CHAPTER.
  
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
  
  
  
  