| 2007-08-02 17:31:50 | DENIED BY BUILDING |
| | |
| | 1) THE NOA HAS EXPIRED. THE WORK IS REQUIRED TO |
| | COMMENCE WITHIN 90 DAYS OF THE RECORDING DATE. THE WILL |
| | NEED TO BE RE-RECORDED. |
| | |
| | 2) THE FINISH FLOOR ELEVATION OF THE ENCLOSED GARAGE IS |
| | REQUIRED TO BE 7'-6" ABOVE BASE FLOOD ELEVATION PER |
| | CITY OF WEST PALM BEACH MUNICIPAL CODE. THE PLANS |
| | SPECIFY THE FINISH FLOOR ELEVATION AS 7.0'. PLEASE |
| | CORRECT. |
| | |
| | 3) THE OWNER/AGENT IS REQUIRED TO SIGN THE ENERGY |
| | CALCULATION FOR. THE FORM IS INCORRECT. THE EXTERIOR |
| | WALLS ARE LISTED ON THE ENERGY CALC. FORM AS WOOD |
| | FRAME. ACCORDING TO THE PLANS ALL OF THE EXTERIOR WALL |
| | ARE MASONRY EXCEPT FOR THE IN-FILL FRAMING AT THE |
| | GARAGE DOOR OPENING. PLEASE CORRECT. |
| | |
| | 4) ITEM #11 FROM THE FIRST REVIEW REQUIRING CLEARANCE |
| | BETWEEN FINAL EARTH GRADE OR SLABS AND EXTERIOR WALL |
| | COVERINGS FOR TERMITE INSPECTIONS HAS NOT BEEN |
| | ADEQUATELYADDRESSED. EXCEPTION #4 WHICH ALLOWS PATIOS |
| | THAT HAVE BEEN SOIL TREATED FOR TERMITES TO MATCH THE |
| | BUILDING INTERIOR FINISH FLOOR ELEVATION, ONLY APPLIES |
| | TO MASONRY CONSTRUCTION. THE AREA AT THE GARAGE OPENING |
| | IS WOOD FRAME. |
| | |
| | 5) IN ORDER TO ADDRESS ITEM #13 FROM THE FIRST REVIEW, |
| | PROVIDE A SECTION THROUGH THE FOUNDATION AT THE WOOD |
| | FRAME IN-FILL WALL AND THE CONCRETE BLOCK WALL SHOWING |
| | COMPLIANCE WITH R404.1.6 . SHOW A MINIMUM OF 4" ABOVE |
| | FINISH GRADE FOR MASONRY AND 6" AT WOOD FRAME. |
| | |
| | 6) THE FLOOR PLAN DOES NOT INDICATE THE WALL TYPES FOR |
| | EXTERIOR OR INTERIOR WALLS. |
| | |
| | 7) PROVIDE WALL SECTIONS WHICH SPECIFY THE EXTERIOR AND |
| | INTERIOR WALL COVERINGS, INSULATION, WATER BARRIER, |
| | LATH AND STUCCO, 1/2" DRYWALL, ETC. |
| | |
| | 8) THE DESCRIPTION OF WORK ON THE APPLICATION INDICATES |
| | ADDING A HOT TUB AND A DECK FOR THE HOT TUB. THE PLANS |
| | THAT WERE SUBMITTED INDICATE THAT THIS IS EXISTING |
| | PLEASE CLARIFY. IF THIS IS NEW WORK TO BE PART OF THIS |
| | PERMIT, SUBMIT THE MANUFACTURER'S SPECS. AND LISTING |
| | INFORMATION FOR THE HOT TUB AND PLANS AND STRUCTURAL |
| | DETAILS FOR THE DECK. SHOW THAT THE DECK IS CAPABLE OF |
| | SUPPORTING THE HOT TUB WITH ASSOCIATED LIVE AND DEAD |
| | LOADS. SPECIFY THE HEIGHT OF THE DECK ABOVE GRADE AND |
| | PROVIDE GUARDRAIL AND STAIR DETAILS IF REQUIRED. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |