| 2007-01-24 10:40:39 | DENIED |
| | REFERENCE: FBC-2004 PLUMBING |
| | FBC-2004 BUILDING |
| | FBC-2004 CHAPTER 1 |
| | FBC-2004 CHAPTER 11 |
| | FLORIDA ADMINISTRATIVE CODE |
| | FLORIDA STATUTES |
| | |
| | 1. SHT A.000 CODE ANALYSIS #1 INDICATES THE AUTHORITY |
| | AS PALM BEACH COUNTY. THE AUTHORITY FOR THIS ADDRESS IS |
| | THE CITY OF WEST PALM BEACH. #2 INDICATES THE FIRE |
| | MARSHALL AS ROBERT PRUSIECKI. HE HAS RETIRED AND THE |
| | NEW FIRE MARSHALL IS MIKE CARCILLO.PLEASE UPDATE THE |
| | INFORMATION ON THE PLANS. SECTION 106.1.1. |
| | |
| | 2. SHT A.000 APPLICABLE BUILDING CODES INDICATES PBC |
| | AMENDMENTS. THIS SHALL BE CHANGED TO WPB AMENDMENTS. |
| | SECTION 106.1.1. |
| | |
| | 3. ALL ARCHITECTURAL SHEETS. THE TITLE BLOCK MUST, AT A |
| | MINIMUM, CONTAIN THE FOLLOWING:THE FIRM LICENSE |
| | NUMBER & THE PRINTED NAME OF THE PERSON SEALING THE |
| | DOCUMENT. FAC 61G1-16.004(2)(6) & FS 481.219, |
| | 481.2055. |
| | |
| | 4. SHT S-1 THE ENGINEER SHALL SIGN/DATE SEALED PLANS. |
| | FAC 61G15-23.002(2) & FS 471.025. |
| | |
| | 5. SHT AD1.03 GENERAL DEMOLITION NOTES 0.1.4 INDICATES |
| | PLUMBING TO BE REMOVED 1/2" BEHIND THE FINISH FACE OF |
| | THE SURFACE. IN THE REMOVAL OF ANY PART OF THE DRAINAGE |
| | SYSTEM, DEAD ENDS ARE PROHIBITED. ALL DEMO'D PIPING |
| | SHALL BE CAPPED AND INSPECTED PRIOR TO COVERING PER |
| | SECTION 704.5. PLEASE INDICATE ON THE DEMO PLANS. |
| | |
| | 6. SHTS A1.03 & A7.031 DETAIL 8. THE PANTRY SINK SHALL |
| | COMPLY WITH SECTION 11-4.24 AND ALL SUBSECTIONS. SHOW |
| | THE FOLLOWING: |
| | A. 11-4.24.3 KNEE CLEARANCE |
| | B. 11-4.24.4 SINK DEPTH |
| | C. 11-4.24.5 CLEAR FLOOR SPACE. FORWARD APPROACH |
| | EXTENDING A MAXIMUM 19" UNDERNEATH THE SINK IS |
| | REQUIRED. CABINET DOORS ARE NOT APPROVED. |
| | D. 11-4.24.6 EXPOSED PIPES & SURFACES |
| | E. 11-4.24.7 FAUCETS |
| | |
| | 7. SHOW THE FIXTURES REQUIRED BY SECTION 1004.1.3 |
| | (BLDG) & 403.1 MINIMUM FACILITIES. INDICATE ON THE |
| | FLOOR PLAN ALL TOILET FACILITIES AND DRINKING |
| | FOUNTAINS. SECTION 106.1.1. |
| | |
| | 8. SHT P2.1 DOMESTIC WATER ISOMETRIC. THE WATER HAMMER |
| | ARRESTORS SHALL BE LOCATED NEAR THE FIXTURES, IN AN |
| | "EFFECTIVE RANGE", NOT IN THE CEILING AS SHOWN. PDI-WH |
| | 201 AND MANUF. INSTALLATION INSTRUCTIONS. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 805-6721 |
| | FAX (561) 805-6731 |
| | E-MAIL [email protected] |