| Plan Review Notes For Permit 06120212 |
| Permit Number |
06120212 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2007-01-26 12:16:42 | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | | | | 1.)DOCUMENTS PREPARED BY AN ARCHITECT AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS FAC61G1-16.003,004. | | | | | | 2.)HOW HAVE YOU ARRIVED AT THE CORNER ZONE PRESSURES | | | FOR THE ROOF?FBC16.PROVIDE CALCULATIONS. | | | | | | 3.)PRODUCT APPROVALS REQUIRED FOR THE ROOF.CHOOSE | | | THE APPROVED ASSEMBLY YOU ARE USING AND SPECIFY | | | ENHANCED FASTENING FOR ZONES 2 AND 3.IF PRODUCT | | | APPROVALS ARE NOT PROPERLY SUBMITTED AND REVIEWED PRIOR | | | TO PERMIT ISSUANCE, A SEPARATE PERMIT WILL BE REQUIRED. | | | | | | | | | 4.)PRODUCT APPROVALS ARE TO BE APPROVED BY DESIGNER | | | OF RECORD, FBC*106.3.3. | | | |
|