| 2007-11-13 07:55:05 | ****************PROVISO**************** | | | (A) 708.3.5 BUILDING DRAIN AND BUILDING SEWER | | | JUNCTION. THERE SHALL BE A TWO-WAY CLEANOUT NEAR THE | | | JUNCTION OF THE BUILDING DRAIN AND THE BUILDING SEWER. | | | | | | (B) 708.7 MINIMUM SIZE. CLEANOUTS SHALL BE THE SAME | | | NOMINAL SIZE AS THE PIPE. | | | **CLEANOUT FOR THE WASHING MACHINE SHALL BE 3 INCH. | | | THEY SERVE UP TO 4 INCHES (102MM) | | | | | | (C) 708.9 ACCESS. ACCESS SHALL BE PROVIDED TO ALL | | | CLEANOUTS. | | | **CLEANOUT FOR THE WASHING MACHINE SHALL BE 4' A.F.F. | | | | | | (D) DISHWASHER DRAIN PER FLOOR PLAN LAYOUT IS LOCATED | | | AT THE OTHER END OF TRIPLE COMPARTMENT KITCHEN SINK. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|