Plan Review Notes
Plan Review Notes For Permit 06120209
Permit Number 06120209
Review Stop B
Sequence Number 1
Notes
Date Text
2007-02-08 09:44:29BUILDING PLAN REVIEW
 PERMIT:06120209
 ADD:1325 9TH STREET
 CONT:JUSTINA A. MCCRAY
 TEL: (561)805-7255
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW1ST
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3)THE EMERGENCY EGRESS WINDOWS SHALL REFER TO
 SECTION R310 OF THE 2004 RESIDENTIAL BUILDING CODE OR
 THE 2004 FBC. NOT THE 2001 FBC.
  
 4)WPB AMENDMENTS 108.3*THE VALUE IS TO LOW. IF IN
 THE OPINION OF THE BUILDING OFFICIAL, THE CLAIMED
 VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL OR PLUMBING SYSTEMS APPEARS
 TO BE UNDERESTIMATED ON THE APPLICATION, THE PERMIT
 SHALL BE DENIED. FOR PERMITTING PURPOSES, VALUATION OF
 BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE
 TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, MECHNICAL,
 INTERIOR FINISH, NORMAL SITE WORK, ARCHITECTURAL AND
 DESIGN FEES EXCLUDING LAND.OUR VALUATION REFERENCE IS
 ICC (BVD) MARSHALL-SWIFT AND MEANS COST ANALYSIS
 SERVICES.
  
 5)R807.1 ATTIC ACCESS. IN BUILDINGS WITH COMBUSTIBLE
 CEILING OR ROOF CONSTRUCTION, AN ATTIC ACCESS OPENING
 SHALL BE PROVIDED TO ATTIC AREAS THAT EXCEED 30 SQUARE
 FEET AND HAVE A VERTICAL HEIGHT OF 30 INCHES OR
 GREATER.
 THE ROUGH-FRAME OPENING SHALL NOT BE LESS THAN 22
 INCHES BY 30 INCHES AND SHALL BE LOCATED IN A HALLWAY
 OR OTHER REDAILY ACCESSIBLE LOCATION. A 30-INCH MINIMUM
 UNOBSTRUCTED HEADROOM IN THE ATTIC SPACE SHALL BE
 PROVIDED AT SOME POINT ABOVE THE ACCESS OPENING. SEE
 SECTION M 1305.1.3 FOR ACCESS REQUIREMENTS WHERE
 MECHANICAL EQUIPMENT IS LOCATED IN ATTICS.
  
 6)106.3.3* PRODUCT APPROVALS- 2004
 THOSE PRODUCTS THAT ARE RGULATED BY DCA
 RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITTING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL. PROVIDE THE PRODUCT APPROVALS
 FOR THE GLASS BLOCKS.
  
 7)M1506.2EXHAUST AIR FROM BATHROOMS AND TIOLET
 ROOMS SHALL NOT BE RECIRCULATED WITHIN A RESIDENCE OR
 TO ANOTHER DWELLING UNIT. MECHANICAL EXHAUST CAPACITY
 FOR BATHROOMS AND TOILET ROOMS SHALL BE NO LESS THAN 50
 CFM INTERMITTENT OR 20 CFM CONTINOUS.
  
 8)R308.4 (5)GLAZING IN DOORS AND ENCLOSURES FOR HOT
 TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND
 SHOWERS. GLAZING IN ANY PART OF A BUILDING WALL
 ENCLOSING THESE XOMPARTMENTS WHERE THE BOTTOM EXPOSED
 EDGE OF THE GLAZING IS LESS THAN 60 INCHES MEASURED
 VERTICALLY ABOVE THE STANDING OR WALKING SURFACE.
  
 9)WPB AMENDMENTS 106.1.3*THE BUILDING OFFICIAL MAY
 ESTABLISH THROUGH DEPARTMENTAL POLICY, STANDARDS FOR
 PLANS AND SPECIFICATIONS, IN ORDER TO PROVIDE
 COMFORMITY TO ITS RECORD RETENTION PROGRAM,THIS
 POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, SHAPE,
 CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO RECORDS
 MANAGEMENT. THE SEAL ON THE DRAWINGS ARE ILLEGIBLE.
 61G15-23.002A PROFESSIONAL ENGINER SHALL SIGN HIS
 NAME AND AFFIX HIS SEAL TO ALL PLANS, SEPCIFICATIONS,
 REPORTS, FINAL BID COCUMENTS OR OTHER DOCUMENTS
 PREPARED OR ISSUED BY SAID REGISTRANT AND BEING FILED
 FOR PUBLIC RECORD.
  
 10)PROVIDE AN INTERIOR ELEVATION SHOWING ALL
 DIMENTIONS OF THE LIVING SPACE CEILING INCLUDED. HOW
 WILL THE EXISTING STRUCTURE BE SUPPORTED WHEN THE
 EXTERIOR WALL AT THE KITCHEN AREA IS REMOVED. SHOW IN
 DETAIL HOW THIS AREA WILL BE SUPPORTED.
  
 11)
 ) 110.2* W. P. B. ADMINISTRATIVE
 CODE, INFORMATION THAT IS REQUIRED FOR
 RECORD KEEPING & FOR CERTIFICATE OF
 OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PERMIT WAS ISSUED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601.
 ) NUMBER OF FLOORS
 ) NUMBER OF ROOMS
 ) NUMBER OF BEDROOMS
 ) SQ. FT. LIV SPACE/ FL
 ) SQ. FT. FOOTPRINT
 ) SQ. FT. UNDER ROOF (TOTAL)
 ) FLOOD ZONE
 ) FLOOD ELEVATION
 )L.O.M.R.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  
  
  
  