Plan Review Notes
Plan Review Notes For Permit 06120149
Permit Number 06120149
Review Stop P
Sequence Number 1
Notes
Date Text
2006-12-27 09:40:25DENIED;
 1.AUTOMATIC CLOTHES WASHER SANITARY DRAIN TO BE REMOVED
 MUST BE REMOVED TO THE BUILDING DRAIN, NO DEAD ENDS
 PERMITED IN THE DRAINAGE SYSTEM. SEE FBC-2004 PLUMBING
 SECTION 704.5 PLEASE ADD NOTE TO PLAN.
 2. NOT ENOUGH INFORMATION TO DO A PLUMBING PLAN REVIEW.
 A SANITARY RISER DIAGRAM IS REQUIRED, SHOWING THE SIZE
 OF THE SANITARY AND VENT PIPING TO BE INSTALLED. SEE
 FBC BUILDING CHAPTER 1 CITY OF WEST PALM BEACH
 ADMINISTRATION CODE SECTION 106.3.5.4(9).
 3. RISER DIAGRAM TO INCLUDE NEW LOCATION OF AUTOMATIC
 CLOTHES WASHER, PLUMBING CODE SECTION 406.3 REQUIRES
 THE BRANCH DRAIN IS REQUIRED TO BE 3" PLEASE SHOW ON
 RISER DIAGRAM.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695