| 2006-12-21 13:22:15 | ** UNSAT ** |
| | |
| | 1) NOTE: PLEASE PROVIDE MAXIMUM TIMES ON OVER |
| | RIDE/MOTION SENSING DEVICES. |
| | PLEASE INDICATE THE LIGHTING POWER DENSITIES FOR AREA. |
| | |
| | PLEASE SEE COMMON ARE CORRIDOR WHICH INDICATE A SWITCH |
| | TYPE OF MOTION DEVICE LOCATED AT ONE END OF AREA. |
| | PLEASE EITHER ADD AN ADDITIONAL DEVICE AT THE OTHER END |
| | OF HALL WAY FOR EGRESS OR PERHAPS A CEILING MOUNTED |
| | DEVICE? 360 DEGREE?PLEASE SEE LS 101 7.8, 7.9 |
| | PLEASE SEE FBC 2004, 13-415.1.ABC.1.1, .1.2 AND .1.3 |
| | 13-415.2.ABC.1 |
| | |
| | 2) NOTE: PLEASE INDICATE THE MINIMUM CIRCUITING ON |
| | PLANS AT THIS TIME AND CORRELATE WITH THE SUBMITTED |
| | PANEL SCHEDULE. IT IS KNOWN TO THIS OFFICE THAT THE |
| | CIRCUITING WILL MOST LIKELY BE REVISED DURING |
| | CONSTRUCTION AND THOSE CAN BE REVISED AT A LATER DATE, |
| | HOWEVER THIS IS REQUIRED AT THIS TIME. |
| | PLEASE SEE THE LIGHTING ON PLANS IS NOT IDENTIFIED ON |
| | PANEL SCHEDULE. |
| | PLEASE BE SURE ROOMS AND AREAS ARE DESIGNATED. IE : |
| | OFFICE #5 RECEPTS, OFFICE LTS ETC. |
| | 408.4, 310.16, 240.4, |
| | FBC 106.1.2, 106.1.3.5.2 |
| | |
| | 3) NOTE: PLEASE BE SURE TO STATE ALL THE RELEVANT CODES |
| | ON PLANS AS FOLLOWS AS THE CODES HAVE CHANGED. |
| | 2002 NEC,(NFPA-70) , 2003 NFPA-101, 2002 NFPA-72 AND |
| | 2004 FBC. |
| | |
| | * ** IMPORTANT** |
| | ONCE ALL REVIEWS ARE DONE AND PLANS ARE |
| | PICKED UP FOR CORRECTIONS, PLEASE BE |
| | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED |
| | SHEETS AND ONLY INSERT NEW REVISED |
| | SHEETS INTO TWO COMPLETE SETS FOR REVIEW |
| | AND STAMPING. DO NOT LEAVE ANY |
| | OLD/VOIDED SHEETS IN SETS. |
| | PLEASE KNOW ONLY ONE SET OF THE |
| | OLD/VOIDED SHEETS SHOULD BE SUBMITTED |
| | FOR REFERENCE. |
| | THIS WILL HELP IN THE REVIEW PROCESS AND |
| | AVOID ANY DELAYS. |
| | |
| | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR |
| | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF |
| | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, |
| | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO |
| | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS |
| | REVIEWER. |
| | |