| Date |
Text |
| 2007-03-20 17:55:23 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBCFLORIDA BUILDING CODE 2004 |
| | FBC EBEXISTING BUILDING |
| | FBC R RESIDENTIAL |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE |
| | FBC2004 |
| | |
| | FROM PREVIOUS REVIEW: |
| | |
| | _XX_5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL |
| | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.NOT |
| | PROVIDED FOR THE INNOVATIVE PRODUCT.IF A FL APPROVAL |
| | IS NOT AVAILABLE, PLEASE ADVISE AND A LOCAL PRODUCT |
| | APPROVAL WILL BE ISSUED USING THE NOA. |
| | |
| | _XX_6.PROVIDE A FLOOR PLAN SHOWING ROOM |
| | DESIGNATIONS.NOTE EXISTING CONDITIONS (TYPE OF |
| | WINDOW) AND OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB |
| | 505.1.TWO SETS REQUIRED.ONE FLOOR PLAN SUBMITTED AS |
| | WELL AS A LETTER AND A LIST OF BEDROOM WINDOWS; PLEASE |
| | SUBMIT TWO COMPLETE COLLATED SETS OF PERMIT DOCUMENTS. |
| | THE FLOOR PLAN IS WITH INNOVATIVE PRODUCT APPROVALS, NO |
| | FL PRODUCT APPROVAL, AND THE LETTERS REGARDING BEDROOM |
| | WINDOWS ARE SEPARATE.IT IS NOT CLEAR WHAT IS TO BE |
| | INCLUDED IN THE PERMIT PACKAGE. |
| | |
| | NEW COMMENTS: |
| | |
| | A.IF THE BEDROOM WINDOW #5 IS A HORIZONTAL ROLLER, |
| | 37X39 ON THE FLOOR PLAN, HOW IS THE CLEAR OPENING |
| | 50X17?#6 HAS A CLEAR OPENING OF 34X17, FLOOR PLAN IS |
| | 53X51.ALL SIZES SHOULD BE WXH, OPENING SIZES DO NOT |
| | CORRELATE WITH WINDOW SIZES. |
| | |
| | B.ONE OF THE PAGES STATES THAT MULL BAR IS REQUIRED, |
| | BUT NO DOUBLE WINDOWS ARE SHOWN ON THE PLAN.SHOW THE |
| | DOUBLE WINDOW ON THE PLAN AND SUBMIT MULLION PRODUCT |
| | APPROVALS. |
| | |
| | |