2007-01-23 17:55:52BUILDING REVIEW CHECKLIST:
 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT AS REQUIRED
 BY SEC. 713.13 FLORIDA STATUTES.
  
 2- PAY IMPACT FEES TO PALM BEACH COUNTY. NEED TO BRING
 BACK STAMPED PLANS AND COPY OF PAID RECEIPT.
  
 3- TRUSSES WILL BE REQUIRED FOR REVIEW PRIOR TO
 INSTALLATION. SEE SEC. R802.10 OF 2004 FLORIDA
 RESIDENTIAL CODE FOR REQUIRED INFORMATION TO BE ON
 TRUSS DRAWINGS. DESIGNER OF RECORD TO REVIEW AND
 APPROVE THEM PRIOR TO SUBMITTAL.
  
 4- PROVIDE DRAINAGE PLANS AS REQUIRED BY SEC. R401.3
 2004 FLORIDA RESIDENTIAL CODE.
  
 ***NOTE: SEE SURVEY FOR FINISH FLOOR ELEVATIONS ON
 ADJACENT PROPERTIES AND PROPOSED FINISH FLOOR ELEVATION
 FOR THIS HOUSE TO AVOID DIVERTING WATER TO ADJACENT
 PROPERTIES.
  
 5- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) FLAT ROOF SYSTEM. SEE ATTACHED COPY OF CITY
 POLICY FOR ROOFING PERMITS FOR REQUIRED INFORMATION.
 FOR FLAT ROOF SYSTEMS NEED TO SELECT SPECIFIC APPROVED
 ASSEMBLY AND FASTENING OPTION. IN ADDITION CHECK IF
 SYSTEM IS LIMITED BY GENERAL LIMITATION #7 OR #9
 (LIMITATION #9 CAN'T BE INSTALLED IN THIS AREA) AND
 PROVIDE REQUIRED INFORMATION ALSO. SEE GENERAL
 LIMITATIONS ON PRODUCT APPROVAL SUBMITTED.
  
 B) POCKET FRENCH SLIDING GLASS DOORS AS SHOWN ON
 PLANS.
  
 C) PARALAM BEAMS AS SHOWN ON PLANS.
  
 D) PRECAST LINTELS AS SHOWN ON PLANS.
  
 E) CONCRETE FLAT ROOF TILE.NOA 01-0417.09 EXPIRED
 ON 06/07/2006.NEED CURRENT PRODUCT APPROVAL. ALSO,
 SPECIFY TILE FASTENING. IF USING POLYFOAM FOR
 ATTACHMENT, THEN PROVIDE PRODUCT APPROVAL FOR
 POLYFOAM.
  
 F) GARAGE DOOR. ES LEGACY REPORT #2318 SUBMITTED
 STATES THAT THIS REPORT BELONGS TO FLORIDA PRODUCT
 APPROVAL FL674. THERE ARE NOT RECORDS FOR FL674.GO TO
 WWW.FLORIDABUILDING.ORG TO VERIFY INFORMATION. PROVIDE
 CURRENT GARAGE DOOR PRODUCT APPROVAL.
  
 G) 3'-6" X 8'-0"***INSWING*** MAHOGANY ENTRY DOOR
 AS SHOWN ON PLANS.
  
 H) 3'-0" X 6'-8"***INSWING*** ENTRY DOOR AT GUEST
 SUITE AS SHOWN ON PLANS.
  
 I) ENTRY DOOR SIDELITES.
  
 J) DOOR AND WINDOW STRUCTURAL MULLIONS AND SPECIFY
 FASTENING.
  
 K) FIXED WINDOWS AS SHOWN ON PLANS.
  
 6- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 7- PROVIDE MANUFACTURER'S SPECS THAT ALLOWS DECORATIVE
 CHIMNEY CAPS. THEN, PROVIDE COMPLETE SPECS SUCH AS
 CLEARANCES, MATERIALS ETC. SEC. 106.1.2 CITY AMENDMENTS
 TO FBC 2004.
  
 8- PROVIDE COMPLETE STRUCTURAL SECTION THRU FIREPLACE
 AND CHIMNEY. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 9- PROVIDE COMPLETE SPECIFICATIONS AND UL LISTING FOR
 BBQDESIGNED TO BE INSTALLED IN THE LOGGIA. SEC.
 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 10- SHEET A-0:A) NAME OF SOIL TEST ENGINEER DOESN'T
 MATCH NAME OF COMPANY WHO SUBMITTED THE SOIL TEST
 REPORT. REVISE AS REQUIRED.
  
 B) NAME OF SURVEYOR DOESN'T MATCH NAME OF SURVEYOR
 WHO SUBMITTED SURVEY. REVISE AS REQUIRED.
  
 C) PROPOSED FINISH FLOOR ELEVATIONS DON'T MATCH
 PROPOSED FINISH FLOOR ELEVATIONS SHOWN ON SURVEY.
 REVISE EITHER ONE TO MATCH.
  
 11- SHEET A-1:NOTE BY LOGGIA AREA CALLS FOR CENTER
 LINE OF FIREPLACE AND CABANA DOORS. WHERE IS THE
 FIREPLACE?. REVISE AS REQUIRED.
  
 12-PROVIDE HANDRAIL AND GUARDRAILS DETAILS SHOWING
 DESIGN LOADS COMPLIANCE AS REQUIRED BYSEC. 1607.7.1
 FBC 2004 AND SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 13- CONTRACTOR'S WORKER'S COMPENSATION INSURANCE IS
 EXPIRED. UPDATE INFORMATION WITH PERMIT CLERK.
  
 14- EXTERIOR ELEVATIONS, WALL SECTIONS AND DETAIL CALL
 FOR DIFFERENT ROOF SHEATHING SIZE. SOME CALL FOR 3/4"
 PLYWOOD AND SOME CALL FOR 5/8" PLYWOOD. REVISE THEM ALL
 AS REQUIRED TO MATCH.
  
 15- SPECIFY FIREBLOCKING INALL WALL SECTIONS AS
 REQUIRED BY SEC. R602.8 OF 2004 FLORIDA RESIDENTIAL
 CODE.
  
 16- PROVIDE COMPLETE SPECS AND INSTALLATION FOR
 COLONIAL SHUTTERS SHOWN ON ELEVATIONS.SEC. 106.1.2
 CITY AMENDMENTS TO FBC 2004 ANDSEC. R301 FOR WIND
 LOADS. AND, CLARIFY IF DECORATIVE SHUTTERS OR
 STRUCTURAL SHUTTERS. STRUCTURAL SHUTTERS REQUIRE
 PRODUCTAPPROVAL AND COMPLETE INSTALLATION SCHEDULE.
  
 17- PROVIDE ATTIC VENTILATION CALCULATIONS AND VENT
 SIZES AND LOCATION TO COMPLY WITH SEC. R806 OF 2004
 FLORIDA RESIDENTIAL CODE.
  
 18- PROVIDE SPECIFICATIONS FOR GARAGE INTERIOR DOOR TO
 COMPLY WITH SEC. R309.1 2004 FLORIDA RESIDENTIAL CODE.
  
 19- PROVIDE SPECIFICATIONS FOR RAIN DOWNSPOUTS TO
 COMPLY WITH SEC. R320.7 2004 FLORIDA RESIDENTIAL CODE.
  
 20-MASTER WALK-IN-CLOSET; SPECIFY SIZE OF ATTIC
 ACCESS TO COMPLY WITH SEC. R807 2004 FLORIDA
 RESIDENTIAL CODE.
  
 21- WALL SECTIONS: SPECIFY MINIMUM FOOTING DEPTH BELOW
 GRADE AND MINIMUM. HEIGHT ABOVE GRADE AS REQUIRED BY
 SEC. R403.1.4ANDSEC. R404.1.6OF 2004 FLORIDA
 RESIDENTIAL CODE.
  
 22- WINDOW AND DOOR DETAILS ON SHEET A-12 DON'T APPLY
 TO THIS JOB. DELETE AS REQUIRED.PROVIDE ONLY THE
 DETAILS THAT APPLY TO THIS JOB.
  
 23- SHEET S-2:A) THERE ARE SOME DETAILSTHAT ARE
 KEYED FOR SHEET S-6. THERE IS NOT SHEET S-6. REVISE AS
 REQUIRED.EG: 3/S-6 AND 4/S-6.
  
 B) CONNECTORS M AND N ARE FOR WOOD TO WOOD
 CONNECTIONS. NEED TO SPECIFY WOOD TO MASONRY CONNECTORS
 AS REQUIRED.SEE SIMPSON CATALOGUE FOR PROPER MASONRY
 CONNECTOR AND TYPE AND NUMBER OF FASTENERS.OTHERWISE,
 PROVIDE COMPLETE ENGINEERING ANALYSIS FOR CONNECTORS
 AND FASTENERS THAT ARE DIFFERENT THAN THOSE TESTED AND
 PUBLISHED BY THE MANUFACTURER. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 C) SPECIFY SPECIFIC SIMPSON HANGER FOR STAIRS 2X12
 CARRIAGES.
  
 D) SPECIFY CONNECTORS FOR GIRDER TRUSSES ENDS BY
 STAIRWAY AND GIRDER TRUSS END BYFAMILY ROOM AREA. SEE
 PLANS FOR COMMENTS.
  
 24- SHEET S-3:A) COORDINATE LOCATION OF ATTIC ACCESS
 BY MASTER BEDROOM WITH ARCHITECTURAL DRAWINGS.
  
 B) WHERE ARE DETAILS 2/S-6. THEREIS NOT SHEET
 S-6.
  
 C) SPECIFY UPLIFT LOAD AND CONNECTOR FOR GIRDER
 TRUSS RESTING ON CHIMNEY SIDE. SEE PLANS FOR COMMENTS.
  
 D) CLARIFY DETAIL 4/S-5 KEYED ON LEFT BOTTOM CORNER
 OF GUEST SUITE ROOF.DETAIL 4/S-5 IS FOR A BUCKET
 DETAIL. CLARIFY/REVISE AS REQUIRED.
  
 E) SPECIFY LEDGER SIZE AND FASTENERS AROUND CHIMNEY
 TO RECEIVE ROOF TRUSSES. SEE PLANS.
  
 25- SHEET S-4:A) REVISE STRUCTURAL NOTES. CLEARLY
 INDICATE DESIGN CRITERIA AS REQUIRED BY SEC. R301 OF
 2004 FLORIDA RESIDENTIAL CODE. INCLUDE ALL LOADS
 INCLUDING LIVE AND DEAD LOADS. AND, ATTIC LIVE LOADS
 FOR ATTIC WITH STORAGE AND ATTICS WITHOUT STORAGE AS
 REQUIRED BY TABLE R301.5 2004 FLORIDA RESIDENTIAL CODE.
 SPECIFY ALL LOADS. EG:ALL DEAD LOADS PLUS 30PSF LIVE
 LOAD FOR ROOF IS NOT PROVIDING ALL NECESSARY
 INFORMATION. REVISE ALL INFORMATION AS REQUIRED.
  
 B) INCLUDE 2004 FLORIDA RESIDENTIAL CODE WHICH IS
 THE CODE THAT APPLIES TO ONE AND TWO FAMILY DWELLINGS.
  
 C) NOTE I REFERS TO SOIL TEST REPORT BY ARDAMAN AND
 ASSOCIATES. THIS IS NOT THE SOIL TEST REPORT SUBMITTED
 WITH PLANS. REVISE/COORDINATE AS REQUIRED. SEE PROVIDED
 SOIL TEST REPORT.
  
 26- ENERGY CALCULATIONS:A) REVISE CONDITIONED AREA TO
 MATCH ARCHITECTURAL DRAWINGS.
  
 B) REVISE UNDER ATTIC AREA. SEE ARCHITECTURAL
 PLANS.
  
 C) CLARIFY WHERE ARE THE SINGLE ASSEMBLY AREAS.
  
 D) REVISE INFORMATION ON TOP OF FORM.THE
 PERMITTING OFFICE IS WEST PALM BEACH NOT PALM BEACH
 COUNTY AND THE CORRECT JURISDICTION # IS 604700 NOT
 601000.
  
 27- SURVEY SUBMITTED;A) SURVEY TO HAVE ORIGINAL
 SIGNATURE (NOT COPY) AS REQUIRED BY CHAPTER 472 FLORIDA
 STATUTES.
  
 B) PROPERTY IS LOCATED ON FLOOD ZONE "B" NOT "A5".
 SEE MAP DATED MARCH 1, 1979.REVISE AS REQUIRED.
  
 C) PROVIDE COMPLETE INFORMATION FOR FLOOD MAP.
 INCLUDE SUFFIX AND DATE OF MAP .
  
 D) SURVEY IS MISSING THE DIMENSIONS FOR THE COVERED
 REAR PORCH.
  
 28- SOIL TEST REPORT SUBMITTED: A) ENGINEER TO PROVIDE
 ORIGINAL SIGNATURE, NOT COPY AS REQUIRED BY CHAPTER 471
 FLORIDA STATUTES AND FLORIDAADMINISTRATIVE CODE.
  
 B) NEED THE FIRM'S CERTIFICATE OF AUTHORIZATION
 NUMBER IN THE LETTERHEAD AS REQUIRED BY SEC.
 61G15-23.002 OF FLORIDA ADMINISTRATIVE CODE.
  
  
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712