| 2007-04-09 15:51:27 | BUILDING PLAN REVIEW |
| | PERMIT:06120055 |
| | ADD: 6 LA COSTA CIRCLE |
| | CONT: AM CONSTRUCTION GROUP INC. |
| | TEL: (561)262-7874 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2006 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW3 RD |
| | ACTION: DENIED |
| | |
| | NOTE: ONE SET OF THE DRAWINGS WHICH WAS PUT TOGETHER BY |
| | OUR OFFICE STAFFWILL BE DETAINEDAND IF NECESSARY |
| | THEY WILL BE SENT TO THE STATE FOR REVIEW DUE TO |
| | REPATED CODE COMMENTS. |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2)OK |
| | |
| | 3)FL S S 713.13 |
| | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF |
| | THE COURT. |
| | NOTE: 713.13(2) |
| | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS |
| | NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE |
| | RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: |
| | 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT |
| | THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| | |
| | 4)OK. |
| | |
| | 5)OK. |
| | |
| | 6)WPB ADMIN CODE 106.3* PRODUCT |
| | APPROVALS. THOSE PRODUCT WHICH ARE |
| | REGULATED BY DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| | FOR JURISDICTIONAL APPROVAL. THE PRODUCT SHALL BE |
| | APPROVED IN WRITING BY THE DESIGNER. |
| | |
| | 7)OK. |
| | |
| | 8)OK. |
| | |
| | 9)ON SHEET S4, INDICATE WHICH STEEL COLUMN IS #1 / #2 |
| | / AND #3. THE COLUMNS ARE THERE ON THE SHEET BUT THEY |
| | ARE NOT LABELED. |
| | |
| | 10)R807.1 INDICATE THE ATTIC ACCESS ON THE DRAWINGS. |
| | THE ROUGH OPENING SHALL NOT BE LESS THAN 22 INCHES BY |
| | 30 INCHES AND SHALL BE READILY ACCESSIBLE. |
| | |
| | 11)G2447.1 (623.1) COOKING APPLIANCES . |
| | COOKING APPLIANCES THAT ARE DESIGNED FOR PERMANENT |
| | INSTALLATION, INCLUDING RANGES, OVENS, STOVES, |
| | BROILERS, GRILLS, FRYERS, GRIDDLES, HOT PLATES AND |
| | BARBECUES, SHALL BE TESTED IN ACCORDANCE WITH ANSI |
| | Z21.1 OR ANSI Z21.58 AND SHALL BE INSTALLED IN |
| | ACCORDANCE WITH THE MANUFACTURER?S INSTALLATION |
| | INSTRUCTIONS. PROVIDE THE MANUFACTURER,S INSTALLATION |
| | INSTRUCTIONS INSTRUCTIONS FOR THE BBQ GRILL. SEE THIS |
| | SECTION FOR MORE INFORMATION. |
| | |
| | 12)PROVIDE AN ABBREVATION LEGEND FOR ALL THE |
| | ABBREVIATION SHOWN ON THE DRAWINGS.106.1.2*THE |
| | BUILDING OFFICIAL MAY REQUIRE DETAILS, AND OTHER DATA |
| | NECESSARY TO DESCRIBE THE CONSTRUCTION OR INSTALLATION |
| | AND THE BASIS OF CALCULATIONS. |
| | |
| | 13)R802.1.6.1 TRUSS DESIGN DRAWINGS, PREPAARED IN |
| | CONFORMANCE WITH SECTION R802.1.6.1 SHALL BE PROVIDED |
| | TO THE BUILDING OFFICIAL AND APPROVED PRIOR TO |
| | INSTALLATION. |
| | |
| | 14) OK. |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | 805-6726 |
| | |
| | |