Plan Review Notes
Plan Review Notes For Permit 06111071
Permit Number 06111071
Review Stop Z
Sequence Number 3
Notes
Date Text
2008-01-16 18:27:20 
 PLANNING AND ZONING:**** FAILED ****
  
 1.PROVIDE RESPONSE TO COMMENTS IN WRITING.
  
 2, (REPEAT COMMENT HAS NOT BEEN ADDRESSED)
 ARCHITECTURAL SHEET AC102 (CONSTRUCTION SET), DETAIL #6
 - DUMPSTER ENCLOSURE PLAN DOES NOT MEET THE MINIMUM
 DEPTH REQUIREMENTS OF 13'-8". PLEASE REFER TO THE
 APPROVED SITE PLANS, SUBMITTED TO THE PLANNING AND
 ZONING DEPARTMENT.
  
 SHEET AC-102 (PERMIT SET) ORIGINALLY SUBMITTED WITH
 THIS BLDG. PERMIT DOES NOT COMPLY WITH THE DUMPSTER
 ENCLOSURE MINIMUM DIMENSIONS.THE REFUSE/STORAGE AREA
 IS LOCATED ADJACENT TO THE HOMEWOOD SUITES HOTEL.A
 DETAIL OF THE PLAN WAS PROVIDED AND LABELED AS
 "EXTERIOR REFUSE RECEPTACLE/STORAGE PLAN" WITH
 ELEVATIONS AND SECTION (ALL LABELED AS DETAIL 1, 2 AND
 3).SEPARATE SHEETS (AC101 AND 102-CONSTRUCTION SET)
 WERE SUBMITTED BY THE PVFS ARCHITECTS A COUPLE OF DAYS
 AGO, TO REPLACE THE PERMIT SET THAT WOULD COMPLY WITH
 THE ZONING CODE, HOWEVER, THE SHEETS THAT WERE
 SUBMITTED ARE DIFFERENT FROM WHAT THE SITE PLAN CALLS
 OUT FOR.SHEET AC102 HAS A LABEL UNDERNEATH WHICH HAS
 ("CONSTRUCTION SET"), ALL THE DETAILS ARE DIFFERENT.
 THE REFUSE/STORAGE COMBINATION STRUCTURE IS NOT SHOWN,
 INSTEAD, A TYPICAL DUMPSTER DETAIL IS SHOWN.
  
 ADDITIONALLY, THE REFUSE/STORAGE NEEDS TO BE MOVED AWAY
 FROM ADJACENT PARKING SPACE, SINCE ACCESS TO THE
 DUMPSTER ENCLOSURE CAN BE BLOCKED OFF IF A CAR IS
 PARKED IN THAT SPACE.ALL SHEETS INCLUDING BUT NOT
 LIMITED TO THE FOLLOWING SHEETS WILL NEED TO REFLECT
 THE REVISED LOCATION (I.E. CIVIL SHEETS 2 OF 9
 (DRAINAGE), 5 OF 9 (POLLUTION), 6 OF 9; ARCHITECTURAL,
 SITE PLAN SP-1 (WITH LATEST REVISION 1-04-08), AND
 LANDSCAPING, LP-1, THE PROPOSED DAHOON HOLLY TREE WILL
 NEED TO BE SHIFTED A LITTLE TO ACCOMMODATE THE
 DUMPSTER.STORAGE ENCLOSURE.)
  
 3.PROVIDE AN EXTRA COPY OF THE SP-1 AND LP-1 TO
 PLANNING AND ZONING DEPARTMENT TO REFLECT REQUIRED
 CHANGES, INCLUDING THE REFUSE/STORAGE DETAILS AND
 REVISED LOCATION WHEN RE-SUBMITTING OR SUBBING SHEETS.
  
 4.PERMIT NO. 06111067- SPRINGHILL HOTEL SHALL REFLECT
 THE SAME CHANGES ON THE SITE PLAN SHEETS AND PERTINENT
 SHEETS ACCORDINGLY.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT.
  
 LINDA MIA FRANCO
 SENIOR PLANNER
 PLANNING AND ZONING DEPARTMENT
 OFFICE: (561) 822-1443
 EMAIL: [email protected]