| 2006-12-18 09:40:46 | BUILDING PLAN REVIEW |
| | PERMIT:06110708 |
| | ADD:299545TH STREET |
| | CONT: B & M CONSTRUCTION CO. INC. |
| | TEL: (954)427-4886 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW1ST |
| | ACTION: DENIED |
| | |
| | |
| | 1)FL S S 713.13 |
| | NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT BEFORE A |
| | PERMIT WILL BE ISSUED. NOTE: 713.13(2) |
| | IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS |
| | NOT ACTUALLY COMMENCED |
| | WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. |
| | |
| | 2)NOTE: A DEMOLITION PERMIT IS REQUIRED FOR THE |
| | INTERIOR DEMOLITION. |
| | |
| | 3)FBC. 11.7IN ADDITION TO THE REQUIREMENTS OF |
| | SECTION 11-4.1 TO 11-4.35 THE DESIGN OF ALL AREAS USED |
| | FOR BUSINESS TRANSACATION WITH THE PUBLIC SHALL COMPLY |
| | WITH SECTION 11-7.PROVICE THE ELEVATION DRAWINGS |
| | SHOWING ALL REQUIRED DIMENTIONS FOR COUNTERS AND |
| | CHECK-OUT AISLES.NOTE THE ATM MACHINE SHALL MEET ALL |
| | ACCESSIBILITY REQUIREMENTS. |
| | |
| | 4)106.3.3* PRODUCT APPROVALS- 2004 |
| | THOSE PRODUCTS THAT ARE RGULATED BY DCA |
| | RULE 9B-72 SHALL BE REVIEWED AND |
| | APPROVED IN WRITTING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL.THE DESIGN PRESSURE ON THE |
| | STOREFRONTS PRODUCT ARE LOW COMPARE TO THE WALL |
| | PRESSURES LISTED IN FBC. TABLE 1609.6.2.1 (2) OR TABLE |
| | 1609.6B. IF THE GLAZING AND FRAME OF THE STOREFRONT IS |
| | NON-IMPACT,IMPACT TESTED STORM SHUTTERS WILL BE |
| | REQUIRED AND SHALL BE IN PLACE AT TIME OF C.O. SEE |
| | 1609.1.1 PROTECTION OF OPENINGS. |
| | |
| | 5) THE PROJECT DESCRIPTION OF THE APPLICATION SHALL |
| | INDICATE THE REMOVAL AND REPLACEMENT OF THE STOREFRONT. |
| | IF THE BATHROOMS MEET THE ACCESSIBILITY REQUIREMENTS |
| | AND NO WORK WILL BE CARRIED OUT THERE, REMOVE OR STRIKE |
| | BATHROOMS FROM THE DESCRIPTION. |
| | |
| | 6)W.P.B AMENDMENTS. 108.3* THE VALUE IS INDICATED IS |
| | LOW.FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| | AND SUSTEMS SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE |
| | STRUCTURAL,ELECTRIC, PLUMBING, MECHANICAL, INTERIOR |
| | FINISH, ARCHITECTURAL AND DESIGN FEES, MARKETING |
| | COSTS,OVERHEAD AND PROFIT EXCLUDING LAND VALUE.IF, IN |
| | THE OPINION OF THE BUILDING OFFICIAL, THE CLAIMED |
| | VALUATION OFBUILDING, ALTERATION,STRUCTURE, |
| | ELECTRICAL, GAS, MECHANICAL OR PLUMBING SYSTEMS APPEARS |
| | TO BE UNDERESTIMATED ON THE APPLICATION, THE PERMIT |
| | SHALL BE DENIED. |
| | |
| | 7)2004 FL. BLD CODE 1603.1.4 THE |
| | FOLLOWING INFORMATION RELATED TO WIND |
| | SHALL BE SHOWN ON THE CONSTRUCTION |
| | DRAWINGS, |
| | 1)- BASIC WIND SPEED, MPH |
| | 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| | CATEGORY |
| | 3)- WIND EXPOSURE |
| | 4)- INTERNAL PRESSURE COEFFICIENT, |
| | 5)- COMPONENTS & CLADDING, THE DESIGN |
| | WIND PRESSURES IN TERMS OF PSF. |
| | |
| | 8)WHAT IS THE DESIGN OCCUPANT LOAD, SEE 1004. |
| | OCCUPANT LOAD |
| | |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | 805-6726 |
| | |
| | |
| | |