Plan Review Notes
Plan Review Notes For Permit 06110708
Permit Number 06110708
Review Stop B
Sequence Number 1
Notes
Date Text
2006-12-18 09:40:46BUILDING PLAN REVIEW
 PERMIT:06110708
 ADD:299545TH STREET
 CONT: B & M CONSTRUCTION CO. INC.
 TEL: (954)427-4886
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW1ST
 ACTION: DENIED
  
  
 1)FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS
 NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
  
 2)NOTE: A DEMOLITION PERMIT IS REQUIRED FOR THE
 INTERIOR DEMOLITION.
  
 3)FBC. 11.7IN ADDITION TO THE REQUIREMENTS OF
 SECTION 11-4.1 TO 11-4.35 THE DESIGN OF ALL AREAS USED
 FOR BUSINESS TRANSACATION WITH THE PUBLIC SHALL COMPLY
 WITH SECTION 11-7.PROVICE THE ELEVATION DRAWINGS
 SHOWING ALL REQUIRED DIMENTIONS FOR COUNTERS AND
 CHECK-OUT AISLES.NOTE THE ATM MACHINE SHALL MEET ALL
 ACCESSIBILITY REQUIREMENTS.
  
 4)106.3.3* PRODUCT APPROVALS- 2004
 THOSE PRODUCTS THAT ARE RGULATED BY DCA
 RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITTING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.THE DESIGN PRESSURE ON THE
 STOREFRONTS PRODUCT ARE LOW COMPARE TO THE WALL
 PRESSURES LISTED IN FBC. TABLE 1609.6.2.1 (2) OR TABLE
 1609.6B. IF THE GLAZING AND FRAME OF THE STOREFRONT IS
 NON-IMPACT,IMPACT TESTED STORM SHUTTERS WILL BE
 REQUIRED AND SHALL BE IN PLACE AT TIME OF C.O. SEE
 1609.1.1 PROTECTION OF OPENINGS.
  
 5) THE PROJECT DESCRIPTION OF THE APPLICATION SHALL
 INDICATE THE REMOVAL AND REPLACEMENT OF THE STOREFRONT.
 IF THE BATHROOMS MEET THE ACCESSIBILITY REQUIREMENTS
 AND NO WORK WILL BE CARRIED OUT THERE, REMOVE OR STRIKE
 BATHROOMS FROM THE DESCRIPTION.
  
 6)W.P.B AMENDMENTS. 108.3* THE VALUE IS INDICATED IS
 LOW.FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SUSTEMS SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL,ELECTRIC, PLUMBING, MECHANICAL, INTERIOR
 FINISH, ARCHITECTURAL AND DESIGN FEES, MARKETING
 COSTS,OVERHEAD AND PROFIT EXCLUDING LAND VALUE.IF, IN
 THE OPINION OF THE BUILDING OFFICIAL, THE CLAIMED
 VALUATION OFBUILDING, ALTERATION,STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL OR PLUMBING SYSTEMS APPEARS
 TO BE UNDERESTIMATED ON THE APPLICATION, THE PERMIT
 SHALL BE DENIED.
  
 7)2004 FL. BLD CODE 1603.1.4 THE
 FOLLOWING INFORMATION RELATED TO WIND
 SHALL BE SHOWN ON THE CONSTRUCTION
 DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 8)WHAT IS THE DESIGN OCCUPANT LOAD, SEE 1004.
 OCCUPANT LOAD
  
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  
  
  