| Date |
Text |
| 2007-01-26 14:18:18 | DENIED 2ND TIME |
| | REFERENCE: FBC-2004 PLUMBING AB FBC-2004 BUILDING |
| | |
| | THE FOLLOWING CORRECTION IS STILL REQUIRED FOR PLUMBING |
| | PLAN REVIEW TO MEET CODE COMPLIANCE: |
| | |
| | 1. THE PERMIT BEING APPLIED FOR IS DEFINED IN THE |
| | FBC-2004 BUILDING SECTION 424.1 AS AN "INTERACTIVE |
| | WATER FEATURE" WHICH MEANS A STRUCTURE DESIGNED TO |
| | ALLOW FOR RECREATIONAL ACTIVITIES WITH RECIRCULATED, |
| | FILTERED, AND TREATED WATER; BUT HAVING MINIMAL |
| | STANDING WATER. WATER FROM THE INTERACTIVE FOUNTAIN |
| | TYPE FEATURES IS COLLECTED BY GRAVITY BELOW GRADE IN A |
| | COLLECTOR TANK OR SUMP. THE WATER IS FILTERED, |
| | DISINFECTED AND THEN PUMPED TO THE FEATURE DISCHARGE |
| | HEADS. THE SUBMITTED DRAWINGS INDICATE THE WATER BEING |
| | CONTINUOUSLY FED TO THE WATER FEATURES WITHOUT ANY |
| | TREATMENT AND IS A TREMENDOUS WASTE OF WATER. NOTE: |
| | YOUR RESPONSE LETTER STATES "THIS PLAYGROUND IS DEFINED |
| | AS A WATER PLAYGROUND AND IS CONSIDERED AS A DRAIN-AWAY |
| | SYSTEM. THE WATER IS USED ONLY ONCE AND DISCHARGED." |
| | PLEASE GIVE A FBC-2004 CODE REFERENCE INDICATING THIS |
| | IS CODE COMPIANT ON THE RESUBMITTAL. I COULD NOT FIND |
| | IT. AS FOR YOUR REFERENCE TO THIS SAME TYPE OF WATER |
| | PLAYGROUND BEING CONSTRUCTED AT GAINES PARK, PHIPPS |
| | PARK AND SOUTH OLIVE PARK FOR THE CITY OF WEST PALM |
| | BEACH. THIS MAY BE FACT, BUT THAT WAS WORK FROM THE |
| | PAST AND POSSIBLY DIFFERENT CODES. |
| | |
| | 2. (OK) |
| | |
| | 3. (OK) |
| | |
| | THE FOLLOWING IS A NEW COMMENT: |
| | |
| | 4. PLEASE SEE ATTACHED NOTICE FS 553.80 (2) (B) |
| | REGUARDING FOUR (4) TIMES THE FEE. |
| | |
| | **********IMPORTANT INFORMATION |
| | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, |
| | PLEASE REPLACE ONLY SHEETS |
| | WHICH HAVE CHANGED, PLEASE INCLUDE A |
| | TRANSMITTAL LETTER INDICATING HOW EACH |
| | ITEM WAS ADDRESSED AND PROVIDE ONE COPY |
| | OF ALL OLD/VOIDED SHEETS FOR REFERENCE |
| | ONLY. |
| | |
| | END OF COMMENTS: |
| | |
| | REVIEW BY MIKE PERSON |
| | (561) 805-6730 |
| | FAX (561) 805-6731 |
| | E-MAIL [email protected] |
| | UNDER SUPERVISION OF K.STEVENS |
| | (561) 805-6721 |