2007-01-23 14:50:30****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE
 FBC2004
  
 1.)PROVIDE PRODUCT APPROVAL FOR THE NEW WINDOWS.
 IMPACT PROTECTION REQUIRED.IF THE WINDOWS ARE NON
 IMPACT, PROVIDE PRODUCT APPROVAL FOR THE SHUTTERS.
 COMPLETE THE INSTALLATION SCHEDULE IF YOU ARE USING
 SHUTTERS TO COMPLY WITH THE IMPACT REQUIREMENT, SEE
 ATTACHED.
  
 2.)PLANS ARE TO BE ARCHITECTURAL QUALITY AND OF
 SUFFICIENT CLARITY TO SHOW SCOPE OF WORK, FBC*106.1.1.
 PLANS SUBMITTED DO NOT SHOW ALL INFORMATION REQUIRED.
  
 3.)PROVIDE PLANS PREPARED BY A DESIGN PROFESSIONAL,
 FBC*106.1.
  
 4.)THE PLAN VIEW OF THE WEST ELEVATION DOES NOT MATCH
 ELV 2, WEST, AND ELV 1 NORTH PLAN VIEW DOES NOT MATCH
 THE ELEVATION.IT IS NOT CLEAR IF THIS IS AN INTERIOR
 OR EXTERIOR ELEVATION.
  
 5.)IT IS NOT CLEAR HOW THE LOADS WILL BE TRANSFERRED
 TO THE GROUND, CORNER OF THE KITCHEN WHERE YOU ARE
 REMOVING THE SECTION OF WALL.IN OTHER WORDS, WHAT
 WILL HOLD UP THE WALL AT THE CORNER?PROVIDE A
 DETAIL.
  
 6.)ELV 4 SHOWS NEW WINDOWS INSTALLED OVER GLASS
 BLOCK.GLASS BLOCK IS USUALLY NOT STRUCTURAL; WHAT
 WILL SUPPORT THE WINDOWS?PROVIDE A DETAIL.
  
 7.)YOU PROPOSE CUTTING A HOLE IN A WALL, ELV 4.HOW
 WILL THE LOADS (ROOF, WALL ABOVE THE PROPOSED WINDOWS)
 BE TRANSFERRED?PROVIDE A DETAIL.THE PLANS ARE TO
 SHOW ALL INFORMATION REQUIRED TO DETERMINE CODE
 COMPLIANCE.THE APPLICATION STATES THAT THIS IS A NON
 LOAD BEARING WALL.NOTE THAT EVEN IF THIS IS NOT LOAD
 BEARING, THE LOAD OF THE WALL ITSELF MUST STILL BE
 TRANSFERRED TO THE FOUNDATION.
  
 8.)TOP VIEW 2ND FLOOR PLAN DOES NOT MATCH THE FLOOR
 PLAN.ONE SHOWS A BUILDING WHICH IS A SQUARE; THE
 OTHER SHOWS AN L SHAPE.IS THIS A TWO STORY BUILDING?
 ALSO THE L SHAPE SHOWS A PORCH WHICH DOES NOT APPEAR ON
 THE SQUARE BUILDING.
  
 9.)HOW HAVE YOU DETERMINED WHICH STRAP TO USE?
 PROVIDE CALCULATIONS.IN THE CATALOG, THIS IS A WOOD
 TO WOOD CONNECTOR.PROVIDE A TECHNICAL BULLETIN OR
 OTHER INFORMATION FROM THE MANUFACTURER TO SHOW THAT
 THIS STRAP IS ACCEPTABLE IN A WOOD TO MASONRY
 APPLICATION.MANUFACTURER IS TO SPECIFY FASTENING AS
 THIS IS EITHER ENGINEERED OR TESTED.
  
 10.)TOP VIEW APPEARS TO SHOW BOTH THE FLOOR PLAN AND
 THE ROOF FRAMING PLAN.PROVIDE AS SEPARATE PLAN VIEWS.
 THE PORCH DOES NOT APPEAR ON THIS PLAN.ARE THEY TWO
 DIFFERENT UNITS; ONE ON THE FIRST FLOOR, ONE ON THE
 SECOND?
  
 11.)IF THE PORCH IS FULLY ENCLOSED, IS IT ALREADY
 INTERIOR SPACE?EXISTING CONDITIONS NOT CLEAR.
  
 12.)PROVIDE WIND DESIGN CRITERIA FBC R301.
  
 13.)THE APPLICATION STATES THAT YOU ARE REPLACING A
 BROKEN REAR WINDOW.SHOW ON THE PLAN.IF YOU ARE NOT
 PROVIDING IMPACT PROTECTION DUE TO THE EXCEPTION IN FBC
 EB 507.3, PROVIDE CALCULATIONS TO SHOW COMPLIANCE.
  
 14.)ELV 3 SHOWS A DOOR OPENING WHICH WILL BE FRAMED
 IN.PROVIDE A STRUCTURAL DETAIL.NO STRAPS SHOWN.NO
 INFORMATION PROVIDED AS TO HOW THE 2X8S WILL ATTACH TO
 THE BLOCK WALL.
  
 15.)THE ELV 4 SHOWS THREE WINDOWS.WHAT IS BETWEEN
 THE WINDOWS?IF MULLIONS ARE USED TO JOIN WINDOWS,
 PROVIDE A PRODUCT APPROVAL FOR THE MULLIONS.
  
 16.)IS THE PORCH CURRENTLY UNDER AIR?WILL IT NOW BE
 AIR CONDITIONED?
  
 17.)DECLARE GOVERNING CODE, INCLUDING FBC EB.
  
 18.)DECLARE LEVEL OF ALTERATION, FBC EB CHAPTER 3.