| Date |
Text |
| 2007-05-08 12:48:24 | BUILDING PLAN REVIEW |
| | PERMIT: 06110556 |
| | ADD: 2814 S. DIXIE HWY |
| | CONT: KARNS CONST. |
| | TEL: (561)805-7528 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2006 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW: 3RD |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2)OK. |
| | |
| | 3)OK. |
| | |
| | 4)OK. |
| | |
| | 5)WHEN RESUBMITTING, HAVE THE FRONT COUNTER STAFF |
| | ADJUST THE VALUE OF THE PROJECT AND PAY THE ADDITIONAL |
| | FEES ACCORDINGLY. |
| | |
| | 6)SEE INFORMATION ABOUT THE CONSTRUCTION OF THE |
| | DUMPSTER ENCLOSURE IN THE PACKAGE AND FOLLOW THOSE |
| | GUIDELINES. DUMPSTER ENCLOSURE MUST HAVE MINIMUM OF |
| | 12'-6" OPENING BETWEEN THE GATE POSTS. ON SHEET 2 |
| | INDICATE ALL DIMENTIONS FOR THE DUMPSTER ENCLOSURE. |
| | |
| | 7)FBC. 1210.2 WALLS WITHIN 2 FEET OF WATER CLOSETS |
| | SHALL HAVE A SMOOTH, HARD, AND NONABSORBENT SURFACE, TO |
| | A HEIGHT OF 4 FEET ABOVE THE FLOOR, AND EXCEPT FOR |
| | STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS |
| | SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY |
| | MOISTURE. PAINT IS NOT HARD. |
| | |
| | 8)THE PLANS INDICATE IMPACT GLASS, HOWEVER, THE |
| | PRODUCT APPROVALS IS FOR NON-IMPACT GLASS. CLARIFY. |
| | PROVIDE THE CORRECT INFORMATION FOR THE STOREFRONT |
| | GLASS. |
| | |
| | 9)OK. |
| | |
| | 10)IF THE SIDEWALK WILL BE ALTERED THE PLANS SHALL BE |
| | REVIEW BY THE ENGINEERING DEPARTMENT. |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | 805-6726 |
| | |