| Date |
Text |
| 2006-12-04 15:56:24 | DENIED |
| | REFERENCE: FBC-2004 SEC. 424.2 OR FBCR-2004 SEC.4101 |
| | |
| | PLEASE ADJUST YOUR NOTES, DETAILS, OR SUBMITTALS TO |
| | REFLECT THE FOLLOWING INFORMATION REQUIRED FOR PLUMBING |
| | PLAN REVIEW: |
| | |
| | 1) FBC-2004 SEC. 424.2.6.6.5, OR |
| | FBCR-2004 SEC. R4101.6.6.5 WHERE |
| | PROVIDED, THE VACUUM OR PRESSURE CLEANER |
| | FITTING SHALL BE LOCATED AT LEAST 6" AND |
| | NOT GREATER THAN 12" BELOW THE MINIMUM |
| | OPERATING WATER LEVEL OR AS AN |
| | ATTACHMENT TO THE SKIMMER. |
| | NOTE: PLEASE PROVIDE MANUFACTURE CUT SHEET OR LIST MAKE |
| | AND MODEL NUMBER OF CLEANING FITTING ON PRINTS. |
| | |
| | 2) ON SHEET 3 OF 3 THERE IS A HEAT PUMP INDICATED ON |
| | THE ELECTRICAL SCHEMATIC IS THIS PART OF THE POOL? IF |
| | NOT PLEASE REMOVE. IF THIS IS PART OF THE POOL PLEASE |
| | ADD TO PLUMBING SCHEMATIC AND PROVIDE THE FOLLOWING. |
| | A) FBC-2004 SEC. 424.2.14.1, OR |
| | FBCR-2004 SEC. R4101.14.1 SWIMMING POOL |
| | WATER HEATERS SHALL BEAR THE LABEL OF A |
| | RECOGNIZED TESTING AGENCY. (MANUFACTURE |
| | SHEETS REQUIRED, PLEASE SUBMIT) |
| | B) FBC-2004 SEC. 424.2.14.2, OR |
| | FBCR-2004 SEC. R4101.14.2 WATER |
| | RETENTION, PROVIDE A POSITIVE MEANS OF |
| | RETAINING WATER IN THE HEATER WHEN PUMP |
| | IS SHUT OFF.(MANUFACTURE SHEETS |
| | REQUIRED, PLEASE SUBMIT) |
| | C) FBC-2004 SEC. 424.2.14.4, OR |
| | FBCR-2004 SEC. R4101.14.4 CONNECTIONS, |
| | ALL WATER HEATING EQUIPMENT SHALL BE |
| | INSTALLED WITH FLANGES OR UNION |
| | CONNECTIONS ADJACENT TO THE HEATER. |
| | (ADD TO NOTES) |
| | |
| | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, |
| | PLEASE REPLACE ONLY SHEETS |
| | WHICH HAVE CHANGED AND PROVIDE ONE COPY |
| | OF ALL OLD/VOIDED SHEETS FOR REFERENCE |
| | ONLY. |
| | |
| | END OF COMMENTS: |
| | |