| Plan Review Notes For Permit 06110355 |
| Permit Number |
06110355 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2006-12-12 15:54:00 | | | | *** ISSUED PERMIT*** | | | -PLAN REVIEW HISTORY- | | | | | | PERMIT#06110355 | | | ADDRESS: 1400 CENTREPARK 1ST FLOOR LOBBY | | | CONT: PASS INTERNATIONAL | | | TELL NUMBER 954)421-9000 | | | | | | THE ATTACHED COMMENTS ARE PART OF THE | | | PERMIT AND PLAN REVIEW PACKAGE AND ARE | | | NOT TO BE REMOVED FROM THE ISSUED SET OF | | | PLANS.104.2.1.2 ADMINISTRATIVE CODE. | | | | | | FBC*= 2004 FLORIDA BUILDING CODE WITH 2006 REVISIONS | | | | | | BUILDING PROVISOS: | | | | | | 803.1 GENERAL. | | | INTERIOR WALL AND CEILING FINISHES SHALL BE CLASSIFIED | | | IN ACCORDANCE WITH ASTM E 84. | | | SUCH INTERIOR FINISH MATERIALS SHALL BE GROUPED IN THE | | | FOLLOWING CLASSES IN ACCORDANCE | | | WITH THEIR FLAME SPREAD AND SMOKE-DEVELOPED INDEX. | | | CLASS A: | | | FLAME SPREAD INDEX 0-25; SMOKE-DEVELOPED INDEX 0-450. | | | CLASS B: | | | FLAME SPREAD INDEX 26-75; SMOKE-DEVELOPED INDEX 0-450. | | | | | | CLASS C: | | | FLAME SPREAD INDEX 76-200; SMOKE-DEVELOPED INDEX 0-450. | | | | | | | | | | | | 803.4.4 MATERIALS. | | | AN INTERIOR WALL OR CEILING FINISH THAT IS NOT MORE | | | THAN 0.25 INCH (6.4 MM) THICK SHALL BE | | | APPLIED DIRECTLY AGAINST A NONCOMBUSTIBLE BACKING. | | | EXCEPTIONS: | | | 1.CLASS A MATERIALS. | | | 2.MATERIALS WHERE THE QUALIFYING TESTS WERE MADE | | | WITH THE MATERIAL SUSPENDED OR | | | FURRED OUT FROM THE NONCOMBUSTIBLE BACKING. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|