2006-12-11 16:57:30BUILDING PLAN REVIEW
 PERMIT: 06110350
 ADD: 1601 FORUM PLACE SUITE 900/905
 CONT: PASS INTERNATIONAL
 TEL: (561)#702-9668
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2 ) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS
 NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
  
 3) 106.1.2* DISCREPANCY BETWEEN THE PERMIT APPLICATION
 AND ON THE COVER SHEET WHERE THE WORK UNDER THIS
 PERMIT
 IS TO OCCUR.
  
 4)SHEET A-1 INDICATES EXITING THROUGH ROOM 103
 LABELEDTELEPHONE CLOSET.
 THE ELECTRICAL SHEETS ALSO CONFIRM WITH EXITING
 LIGHTING THAT THIS IS A PROPOSED
 EXIT PATHWAY.
 1013.2 EGRESS THROUGH INTERVENING SPACES.
 EGRESS FROM A ROOM OR SPACE SHALL NOT PASS THROUGH
 ADJOINING OR INTERVENING
 ROOMS OR AREAS, EXCEPT WHERE SUCH ADJOINING ROOMS OR
 AREAS ARE ACCESSORY
 TO THE AREA SERVED; ARE NOT A HIGH-HAZARD OCCUPANCY AND
 PROVIDE A DISCERNIBLE
 PATH OF EGRESS TRAVEL TO AN EXIT. EGRESS SHALL NOT PASS
 THROUGH KITCHENS, STORAGE
 ROOMS, CLOSETS OR SPACES USED FOR SIMILAR PURPOSES. AN
 EXIT ACCESS SHALL NOT PASS
 THROUGH A ROOM THAT CAN BE LOCKED TO PREVENT EGRESS.
 MEANS OF EGRESS FROM
 DWELLING UNITS OR SLEEPING AREAS SHALL NOT LEAD THROUGH
 OTHER SLEEPING AREAS,
 TOILET ROOMS OR BATHROOMS.
  
 5) SHEET A-1 THE EXISTING DOOR OF THE TELEPHONE CLOSET
 DOESN'T HAVE THE REQUIRED
 18" LAATCH SIDE OF DOOR.11-4.13.6 MANEUVERING
 CLEARENCES
 AT DOORS. MINIMUM MANEUVERING CLEARANCES
 AT DOORS THAT ARE NOT AUTOMATIC OR
 POWER-ASSISTED SHALL BE AS SHOWN IN
 FIG. 25. THE FLOOR OR GROUND AREA WITH
 IN THE REQUIRED CLEARANCES SHALL BE
 CLEAR & LEVEL.
 THE SECOND ISSUE IS THE FIRE EXTINGUISHER IN THE 18"
 CLEAR FLOOR SPACE.
 11-4.4.1 GENERAL.
 OBJECTS PROJECTING FROM WALLS (FOR EXAMPLE, TELEPHONES)
 WITH THEIR LEADING EDGES BETWEEN 27 INCHES AND 80
 INCHES (685 MM AND 2030 MM) ABOVE THE FINISHED FLOOR
 SHALL PROTRUDE NO MORE THAN 4 INCHES (102 MM) INTO
 WALKS, HALLS, CORRIDORS, PASSAGEWAYS, OR AISLES [SEE
 FIGURE 11-8 (A)]. OBJECTS MOUNTED WITH THEIR LEADING
 EDGES AT OR BELOW 27 INCHES (685 MM) ABOVE THE FINISHED
 FLOOR MAY PROTRUDE ANY AMOUNT [SEE FIGURE 11-8 (A) AND
 FIGURE 11-8 (B)]. FREE-STANDING OBJECTS MOUNTED ON
 POSTS OR PYLONS MAY OVERHANG 12 INCHES (305 MM) MAXIMUM
 FROM 27 INCHES TO 80 INCHES (685 MM TO 2030 MM) ABOVE
 THE GROUND OR FINISHED FLOOR [SEE FIGURE 11-8 (C) AND
 FIGURE 11-8 (D)]. PROTRUDING OBJECTS SHALL NOT REDUCE
 THE CLEAR WIDTH OF AN ACCESSIBLE ROUTE OR MANEUVERING
 SPACE [SEE FIGURE 11-8 (E)].
  
 6) MEP DRAWINGS THE ARCHITECT DOESN'T HAVE HIS PRINTED
 NAME IN THE HEADER STRIP.
 61G1-16.004FL. ADMIN. CODE.PLANS
 PREPARED BY A REGISTERED ARCHITECT SHALL
 INCLUDE A TITLE BLOCK WHICH MUST:
 - STATE THE FIRM NAME, ADDRESS AND
 TELEPHONE NUMBER
 - STATE THE FIRM LICENSE NUMBER
 - STATE PROJECT NAME OR IDENTIFICATION
 - STATE DATE PREPARED
 - INCLUDE AN ORIGINAL SIGNATURE AND
 DATED SEAL
 - INCLUDE THE PRINTED NAME OF THE
 ARCHITECT SEALING THE PLANS
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  