| Plan Review Notes For Permit 06110303 |
| Permit Number |
06110303 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2006-11-28 15:47:07 | | | | *** ISSUED PERMIT*** | | | -PLAN REVIEW HISTORY- | | | | | | PERMIT# 06110303 | | | ADDRESS: 390136TH COURT | | | CONT: MOTIFF GROUP LLC | | | TELL # (561)202-5104 | | | | | | THE ATTACHED COMMENTS ARE PART OF THE | | | PERMIT AND PLAN REVIEW PACKAGE AND ARE | | | NOT TO BE REMOVED FROM THE ISSUED SET OF | | | PLANS.104.2.1.2 ADMINISTRATIVE CODE. | | | | | | | | | PROVISOR: | | | | | | 1008.1.3.5 SECURITY GRILLES. | | | IN GROUPS B, F, M, R AND S, HORIZONTAL SLIDING OR | | | VERTICAL SECURITY GRILLES ARE PERMITTED AT THE MAIN | | | EXIT AND SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE | | | USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT DURING | | | PERIODS THAT THE SPACE IS OCCUPIED. THE GRILLES SHALL | | | REMAIN SECURED IN THE FULL-OPEN POSITION DURING THE | | | PERIOD OF OCCUPANCY BY THE GENERAL PUBLIC. WHERE TWO OR | | | MORE MEANS OF EGRESS ARE REQUIRED, NOT MORE THAN | | | ONE-HALF OF THE EXITS OR EXIT ACCESS DOORWAYS SHALL BE | | | EQUIPPED WITH HORIZONTAL SLIDING OR VERTICAL SECURITY | | | GRILLES. |
|