2007-11-19 16:01:34PERMIT: 06110263
 ADD: 518 S DIXIE HWY
 CONT: ROOSTH CONSTRUCTION
 TEL: (561)221-7721
 DATE: NOV 19, 2007
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 4THREVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2 ) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS
 NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
  
 3) COMPLIED.
  
 4) COMPLIED.
  
 5) COMMENT NUMBER (5) FROM THE PREVIOUS REVIEW, WPB
 ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE PRODUCT
 WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 THE DESIGNER OF RECORD IS TO REVIEW ALL PRODUCT
 APPROVALS REQUIRED BY RULE 9B-72 PLEASE PROVIDE A SHOP
 DRAWING STAMP. IF THE DESIGNER OF RECORD WISHES TO MAKE
 A COVER SHEET LISTING ALL PRODUCTS REVIEWED FOR THIS
 PROJECT, THEN THIS SHEET WOULD NEED TO BE SIGNED AND
 SEALED AND DATED.
  
 6) COMMENT NUMBER (6) FROM THE PREVIOUS REVIEW,DEALS
 WITH THE HURRICANE PREPAREDNESS PLAN. THE ARCHITECT
 INDICATES BY LETTER HE HAS REVIEWED THE INFORMATION
 REQUIRED AND FOUND IT TO BE CODE COMPLIANT, BUT HE
 FAILED TO SIGN AND SEAL SAID LETTER.
 PLEASE SEE THE PLANS DO NOT INDICATE WHERE UNIT 522 S
 DIXIE IS OR WHERE THE SHUTTERS WILL BE STORED.
 WE ALSO FAIL TO SEE A NOTIRIZED LETTER OR ANY CONTRACT
 BETWEEN THE OWNER AND DOMINICK MASSERO FOR THE
 INSTALLATION OF SHUTTERS IN THE EVENT THIS COUNTY IS
 PLACED UNDER A HURRICANE WARNING.
  
 IF THE BUILDING IS TO BE STORM SHUTTERED RATHER THAN
 LARGE IMPACT WINDOWS AND DOORS, THE BUILDING OFFICIALS
 INTERPRETATION
 OF THE CODE REQUIRES A HURRICANE PREPAREDNESS PLAN WITH
 THE FOLLOWING:104.6*/ 1609.1.4/ 1714.5 STANDARDS FOR
 WIND-BORNE DEBRIS IMPACT PROTECTION
 QUESTION# 13 RECOGNIZING SUCH CONCERNS AS ABSENTEE
 OWNERS, OR CASES WHERE LONGER TIME & EFFORT IS
 NECESSARY TO SECURE SHUTTERS ON LARGE OR MULTI-STORY
 BUILDINGS, WHAT MEASURES ARE BEING RECOMMENDED OR
 IMPLEMENTED TO ENSURE THAT COMPLETE INSTALLATION OR
 SECURING IS DONE SUFFICIENTLY IN ADVANCE OF THE
 HURRICANE?
  
 IN MATTERS CONCERNING PUBLIC SAFETY, HEALTH, AND THE
 GENERAL WELFARE NOT SPECIFICALLY ADDRESSED IN THE CODE,
 SECTION 104.6 OF THE FLORIDA BUILDING CODE,BUILDING,
 CHAPTER 1,
 ADMINISTRATIVE CODE2004 EDITION AS AMENDED BY THE CITY
 OF WEST PALM BEACH, PROVDES THE ABILITY FOR THE
 BUILDING OFFICIAL TO IMPLEMENT REQUIREMENTS FOR
 ENSURING STABILITY, STRENGTH, AND THE PROPER OPERATION
 OF EXISTING BUILDINGS.
  
 IN ORDER TO ASSURE THE SECURING OF SHUTTERS ON LARGE OR
 MULTI-STORY BUILDINGS, OR MULTIPLE BUILDINGS ON THE
 SAME PROPERTY, PRE-STORM PREPARATION PLANS MUST BE
 SUBMITTED BY THE PROPERTY OWNERS OR MANAGING AGENTS FOR
 REVIEW BY THE CONSTRUCTION SRVICES DEPARTMENT. ANY SUCH
 PLAN SHALL INCLUDE, AT A MINMUM, ON SITE LOCATION OF
 THE SHUTTERS, PARTY RESPONSIBLE FOR SECURING THE
 SHUTTERS ( SAID PARTY MUST BE LOCATED WITHIN PALM BEACH
 COUNTY), TOTAL NUMBER OF OPENINGS TO BE PROTECTED AND
 THE TOTAL TIME REQUIRED TO SECURE ALL OPENINGS.
 PROTECTION OF OPENINGS SHALL BE ACCOMPLISHEDWITHIN
 TWELVE (12) HOURS OR LESS OF THE
 OFFICIAL NOTIFICATION BY THE NATIONAL WEATHER SERVICES
 OF A HURRICANE WATCH.
  
 PROVISIONS IN THE BUILDING CODES (AND THIS STANDARD)
 ARE NOT INTENDED TO PROHIBIT THE USE OF ALTERNATE
 MATERIALS AND METHODS, AND THE BUILDING OFFICIAL TO
 REVIEW AND APPROVE ANY ALTERNATE DEEMED EQUIVALENT IN
 QUALITY, STRENGTH, EFFECTIVENESS, FIRE RESISTANCE,
 DURABILITY AND SAFETY PRESCRIBED BY THIS CODE. BASED
 UPON THIS CODE PROVISION, ACCEPTANCE OF ALTERNATE
 MATERIALS AND METHODS MAY BE APPROVED ON A CASE-BY-CASE
 BASIS AND SHALL REQUIRE SUFFICIENT EVIDENCE OR PROOF TO
 SUBSTANTIATE ANY CLAIM MADE REGARDING THE ALTERNATE.
  
 7) COMMENT# 7 FROM THE PREVIOUS REVIEW,DEALS WITH A
 KET PLAN INDICATING THE LOCATION OF THE OPENING, AND
 HIGHLIGHTING THE TYPE OF SHUTTER APPLICATION USED IN
 THE INSTALATION, NOR HAS THE TYPE OF FASTENER HIGH
 LIGHTED AND SPACING REQUIREMENTS AS SPECIFIED BELOW.
 PLEASE TAKE THE TIME TO CREATE A SCHEDULE THAT WILL
 CONFORM TO THE CITYS' REQUIREMENTS.
 STORM SHUTTER REQUIREMENTS: 2004FL BLD CODE 2001
 SECTION 104.6, 1609.1.4& 1714.5PROVIDE STORM PANEL
 INFORMATION WITH INSTALLATION SCHEDULE AND KEY PLAN
 WITH SPECIFIC ANCHORS AND MOUNTING TO BE USED FOR ALL
 NON-IMPACT GLAZING.
 FBC 1609.1.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.SEE ATTACHED EXAMPLE.
  
 8)NEW COMMENT, THE NEW FRONT ENTRYS DO NOT MEET THE
 REQUIREMENTS FOR CLEAR FLOOR SPACE AT DOORWAYS.
 11-4.13.6 MANEUVERING CLEARENCES AT DOORS. MINIMUM
 MANEUVERING CLEARANCES AT DOORS THAT ARE NOT AUTOMATIC
 OR POWER-ASSISTED SHALL BE AS SHOWN IN FIG. 25. THE
 FLOOR OR GROUND AREA WITH IN THE REQUIRED CLEARANCES
 SHALL BE CLEAR & LEVEL.
  
  
 JIM WITMER C. B. O.
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]