| Date |
Text |
| 2007-05-10 16:12:42 | |
| | FAILED FOR FOLLOWING REASONS: VERY IMPORTANT,PLEASE |
| | RESPOND EACH ITEM OF THE LINE#. |
| | |
| | 1. PLEASE SHOW ON DRAWINGS ALL STANDARDS NOTES OF CITY |
| | OF WPB FOR SIDEWALK WIDTH , ITS SLOPE, DRIVEWAY, |
| | PARKING, HANDICAP PARKING, PAINTPER CITY CODES |
| | ETC.YOU CAN GET A CD FROM 100045TH STREET ENG.,, MUST |
| | MEETALSO ADA,,STANDARDS AND PLEASE SHOW ON THE |
| | DRAWINGS. |
| | 2. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE |
| | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION |
| | MUST BE ACCESSIBLE FOR PICKUP TRUCK. |
| | 3. PLEASE SHOW ON DRAWINGS FIRST FLOOR ELEVATION, |
| | CENTER LINE OF ROAD ELEVATION , SIDEWALK ELEVATION MUST |
| | MEET FLOOD ZONE OF THAT AREA & FL BLDG CODE.WHAT |
| | CRITERIA YOU USED IN DETERMINING FIRST FLOOR ELEVATION |
| | LIKE 5 YEAR,10 YEAR, 25 YEAR, 100 YEAR FLOOD, PLEASE |
| | SHOW ALL THESE CALCULATIONS,YOU NEED TO USE THE WORST |
| | CASE TO GET SAFER DESIGN FOR FIRST FLOOR ELEVATION. |
| | PLEASE SHOW ON THE DRAWINGSTHAT ON FIRST FLOOR |
| | ELEVATION. |
| | 4. PLEASE PROVIDE A COPY OF SFWMD PERMIT, & GEOTECH |
| | REPORT AGAIN. |
| | 5.IN YOUR STORM WATER QUALITY CALCULATIONS, WHY YOU DID |
| | NOT USE THE WORST CASE FOR SAFER DESIGN, 2.5" CRITERIA, |
| | YOU CALCULATED RETENTION VOLUME 0.45 ACRE-FEET , |
| | INSTEAD YOU USED .07 ACRE-FEET. TO DETERMINE THE LENGTH |
| | OF EXFILTRATION TRENCH,WOULD HAVE BEEN LONGER AND |
| | SAFER IF YOU USED 0.45 ACRE-FEET.. PLEASE EXPLAIN. |
| | PLEASE GET A COPY OF THIS CRITERIA FROM SFWMD FOR |
| | DETAIL CALS & METHODS. |
| | 6. PLEASE PROVIDE ON DRAWINGS THE TOTAL SITE AREA, |
| | PERVIOUS AREA, GREEN, LAKES, ETC,IMPERVIOUS |
| | AREA,BUILDING,PARKING LOT,SIDEWALK ETC. |
| | 7. HOW DIDYOU CONNECT TO THE STORM WATER PIPES IN |
| | YOUR SITE? ITS DETAILS.PLEASE SHOW ALL STORM WATER |
| | PIPES AROUND YOUR SITE SO, WE CANSEE THE BEST STORM |
| | WATER PIPE TO CONNECT WITH THE STORM WATERFROM ALL |
| | OTHER STORM WATER PIPES. PLEASE SHOW DETAIL OF THE |
| | CONTROL STRUCTURES WITH ELEVATIONS, NOTCHES, BLEEDING |
| | ELEVATION, ETC DID YOU USE EXFILTRATION TRENCH ? |
| | 8. POLLUTION PREVENTION DETAILS,CLOTHES USED FOR SILT |
| | ETC., PLANS SHOWING SILT FENCE AROUND THE SITE |
| | 9. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH |
| | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVE |
| | 10. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND |
| | YOUR SITE FOR STORM WATER DRAIN. |
| | |
| | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR |
| | PERMITTING PROCESS. |
| | |
| | RASIK CHOKSHI805-6723 |