| Date |
Text |
| 2009-01-27 11:01:13 | BUILDING PLAN REVIEW |
| | PERMIT: 06110152 |
| | ADD: 821 N. FLAGLER DR. |
| | CONT: ANDERSON-MOORE |
| | TEL: (561)662-1819 |
| | |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS TO THE ADMINISTRATIVE |
| | CODE |
| | |
| | REVISION REVIEW DATED; 10-06-08 |
| | ACTION:DENIED |
| | |
| | 1) SHEET A3.2.1 & A5.2.3 |
| | |
| | A) REVISION# 4 OF THIS SHEET INDICATES THE CHANGE IN |
| | FILL MATERIAL FROM EARTHENED FILL TO A GEO FOAM TO |
| | LESSEN THE LATERAL LOAD OR PRESSURES ON THE STAIR |
| | WALLS. PLEASE PROVIDE DOCUMENTATION THAT THE FOAM WILL |
| | MEET THE REQUIREMENTS OF SUPPORTING 3000 PSF FOUNDATION |
| | NOTES SHEET S-5. SHEET A.5.2.3 DETAIL# 1 INDICATES SEE |
| | STRUCTURAL DRAWINGS. STRUCTURAL SHEET S-2.1 THE WEST |
| | END OF THE SECOND FLOOR SLAB HAS A CUT SECTION DETAIL |
| | 3/ S-9. WHEN REVIEWING THIS DETAIL THE PLANS STILL |
| | INDICATE EARTHENED FILL NOT A GEO FOAM, THE NOTE ON |
| | THIS SHEET INDICATES CONCRETE STAIRS ON GRADE SEE |
| | TYPICAL DETAIL. S-6 . S-6 AGAIN INDICATES EARTHENED |
| | FILL WITH WIRE MESH W.F 6X6 /W1.4XW1.4 NOT A STRUCTURAL |
| | STEEL REINFORCED SLAB. |
| | |
| | B CHAPTER 26 DEALS WITH FOAM PLASTICS WHEN USED IN |
| | CONSTRUCTION OF STRUCTURES AND BUILDINGS. THERE IS NO |
| | SECTION THAT INDICATES THE USE OF FOAM AS A FILLER |
| | BENEATH SLABS BUT TO USE FOAM FOR THIS APPLICATION IT |
| | WILL NEED TO COMPLY WITH 2603.8. SUCH TESTING SHALL BE |
| | RELATED TO THE ACTUAL END-USE CONFIGURATION AND BE |
| | PERFORMED ON THE FINISHED MANUFACTURED FOAM PLASTIC |
| | ASSEMBLY IN THE MAXIMUM THICKNESS INTENDED FOR USE. |
| | |
| | 2) SHEET A4.1.2 |
| | |
| | A) CITY STAMPED SET OF PLANS INDICATES A REVISION# 2 |
| | DATED 7/13/07 MUSIC CLASSROOM # 3 WHERE REVISION# 2 |
| | INDICATES A LEVEL FLOOR. IN TTHE REVISION SET, |
| | REVISION# 3 WHERE THE CITY PLANS SHOW A FLAT FLOOR |
| | SURFACE THE NEW REVISION 3 SET SHOWS DASHED LINES UNDER |
| | REVISION# 2, WHAT APPEARS TO BE RAISED PLATFORM? THIS |
| | WAS AN ISSUE THAT I BELIEVE YOU WERE GOING TO THE STATE |
| | FOR A WAIVER TO THE STATE FOR VERTICAL ACCESSIBILITY, |
| | IF YOU RECEIVED THE WAIVER PLEASE PROVIDE A COPY, IF |
| | NOT REMOVE THE DASHED LINES AS IN THE ISSUED SET OF |
| | PLANS.VERTICAL ACCESSIBILITY 11-4.1.3(5). |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |
| | MEMBER OF BOAF, THE BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA: PROTECTING LIVES AND PROPERTY SINCE 1953. |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. UNDER FLORIDA STATE STATUTE SB 80, E-MAIL |
| | ADDRESSES ARE PUBLIC RECORDS.WRITTEN COMMUNICATIONS TO |
| | OR FROM LOCAL OFFICIALS REGARDING CITY BUSINESS ARE |
| | PUBLIC RECORD, AVAILABLE TO THE PUBLIC UPON REQUEST. |
| | YOUR E-MAIL COMMUNICATIONS ARE THEREFORE SUBJECT TO |
| | PUBLIC DISCLOSURE. |